TY - JOUR
T1 - Stretchable, anti-bacterial hydrogel activated by large mechanical deformation
AU - Ballance, William C.
AU - Seo, Yongbeom
AU - Baek, Kwanghyun
AU - Chalifoux, Madeleine
AU - Kim, Donghyun
AU - Kong, Hyunjoon
N1 - Publisher Copyright:
© 2018 Elsevier B.V.
PY - 2018/4/10
Y1 - 2018/4/10
N2 - Hydrogels have been used extensively to deliver functional molecular cargos in response to external mechanical force. However, the intrinsic brittleness of gels restricts the applicable range of strain to 0.1, thus limiting the range of molecular release rate that may be controlled. Also, uncontrollable molecular diffusion, which is especially prominent in small molecules, reduces the role of mechanical stimulus on the release rate. As such, we hypothesized that these challenges would be resolved by combining cyclodextrin, which may form guest-host complexes with small molecular cargos, with a stretchable hydrogel system. We examined this hypothesis by synthesizing cyclodextrin acrylate and incorporating it into a polyacrylamide gel that can be stretched by 100% of its original length. In the absence of external stretching, hydrogels containing cyclodextrin acrylate with a degree of acryloyl group substitution (DS A ) of 2.3 presented a lower molecular release rate than hydrogels without cyclodextrin acrylate. More interestingly, the polyacrylamide-cyclodextrin hydrogel system displayed an increased molecular release rate corresponding to the degree of stretching, particularly in the gels containing cyclodextrin acrylate with a DS A of 2.3. As such, this stretchable gel loaded with quinine was used to inhibit the growth of E. coli in lysogeny broth only when the gel was stretched. We believe the results of this study would be valuable for improving the quality of controlled molecular delivery and subsequent efficacy of molecular cargos.
AB - Hydrogels have been used extensively to deliver functional molecular cargos in response to external mechanical force. However, the intrinsic brittleness of gels restricts the applicable range of strain to 0.1, thus limiting the range of molecular release rate that may be controlled. Also, uncontrollable molecular diffusion, which is especially prominent in small molecules, reduces the role of mechanical stimulus on the release rate. As such, we hypothesized that these challenges would be resolved by combining cyclodextrin, which may form guest-host complexes with small molecular cargos, with a stretchable hydrogel system. We examined this hypothesis by synthesizing cyclodextrin acrylate and incorporating it into a polyacrylamide gel that can be stretched by 100% of its original length. In the absence of external stretching, hydrogels containing cyclodextrin acrylate with a degree of acryloyl group substitution (DS A ) of 2.3 presented a lower molecular release rate than hydrogels without cyclodextrin acrylate. More interestingly, the polyacrylamide-cyclodextrin hydrogel system displayed an increased molecular release rate corresponding to the degree of stretching, particularly in the gels containing cyclodextrin acrylate with a DS A of 2.3. As such, this stretchable gel loaded with quinine was used to inhibit the growth of E. coli in lysogeny broth only when the gel was stretched. We believe the results of this study would be valuable for improving the quality of controlled molecular delivery and subsequent efficacy of molecular cargos.
KW - Controlled molecular delivery
KW - Cyclodextrin acrylate
KW - E. coli
KW - Quinine
KW - Stretchable hydrogel
UR - http://www.scopus.com/inward/record.url?scp=85041809661&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85041809661&partnerID=8YFLogxK
U2 - 10.1016/j.jconrel.2018.02.009
DO - 10.1016/j.jconrel.2018.02.009
M3 - Article
C2 - 29427648
AN - SCOPUS:85041809661
SN - 0168-3659
VL - 275
SP - 1
EP - 11
JO - Journal of Controlled Release
JF - Journal of Controlled Release
ER -