Skip to main navigation Skip to search Skip to main content

Stark electron density mapping in the high voltage spark discharge

  • Cheryl A. Bye
  • , Alexander Scheeline

Research output: Contribution to journal › Article › peer-review

Abstract

The diagnostic utility of spatial and temporal electron density mapping in the analytical high voltage spark discharge using a charge coupled array detector (CCD) is critically evaluated. Hβ Stark broadening was utilized for electron density measurements where applicable. Quadratic Stark broadening of Ar II was employed in the discharge core, where hydrogen emission is weak. Peak electron density of 1017 cm-3 was found by both probes. Coupling between electron temperature and computed electron concentration is quantitatively evaluated. Neither independent measurement of electron temperature nor Abel inversion is required for adequate understanding of the plasma dynamics as revealed by spatial electron density distributions. There is weak indication of a shock wave, previously reported only in Schlieren photographs, detaching from the spark channel approximately 37 μs after discharge triggering.

Original languageEnglish (US)
Pages (from-to)1593-1605
Number of pages13
JournalSpectrochimica Acta Part B: Atomic Spectroscopy
Volume48
Issue number13
DOIs
StatePublished - Nov 1993

ASJC Scopus subject areas

  • Analytical Chemistry
  • Atomic and Molecular Physics, and Optics
  • Instrumentation
  • Spectroscopy

Fingerprint

Dive into the research topics of 'Stark electron density mapping in the high voltage spark discharge'. Together they form a unique fingerprint.

Cite this