TY - GEN
T1 - Spatially Distributed Measurements of Ejecta Concentrations in Plume-Surface Interactions using Millimeter Wave Interferometry
AU - Rasmont, Nicolas
AU - Al-Rashdan, Hussein T.
AU - Elliott, Gregory S.
AU - Rovey, Joshua L.
AU - Villafañe, Laura
N1 - Publisher Copyright:
© 2023, American Institute of Aeronautics and Astronautics Inc, AIAA. All rights reserved.
PY - 2023
Y1 - 2023
N2 - Millimeter-wave interferometry has shown much promise to measure particle concentrations in opaque, dispersed multiphase flows such as those encountered in plume-surface interactions. This study expands on a previously developed proof-of-concept millimeter-wave interferometer, demonstrating several mission-critical capabilities and providing unique insights in the ejecta dynamics of plume-surface interactions. An innovative vacuum calibration procedure reduced measurement uncertainties by one order of magnitude compared to prior calibrations at ambient conditions thanks to the reduction of aerodynamic entrainment. Calibration experiments verified the theoretical linear relation between phase shift and path-integrated particle number density and provided the constant proportionality factor for the specific glass microspheres and radar system employed. The instrument was demonstrated on a reduced-scale plume-surface interaction experiment. Ejecta path-integrated concentrations were measured at two ambient pressure levels representative of Lunar (14.26 Pa) and Martian (800 Pa) surface conditions, confirming the trends observed during prior experiments. Further experiments were conducted at 800 Pa to demonstrate the capability of the instrument to operate in very close proximity to the ground, and to analyze the distribution of ejecta with altitude. Ejecta path-integrated concentrations measured at 9, 6, and 3 cm above the granular surface provided maximum values of (1.284 ± 0.040) × 109 #.m−2 , (2.345 ± 0.051) × 109 #.m−2 , and (6.881 ± 1.659) × 109 #.m−2 respectively. Ongoing developments of millimeter-wave interferometry for concentration measurements aim at providing the 3D spatial distribution of ejecta cloud concentrations. To that end, a preliminary demonstration of 3D tomographic capabilities was performed using 3 reflectors, each defining a distinct measurement path. A tomographic reconstruction algorithm was implemented to convert path-integrated concentrations into standard concentrations, providing a maximum of (10.140 ± 0.442) × 109 #.m−3 measured at a radial distance of 8.8 cm from the nozzle axis.
AB - Millimeter-wave interferometry has shown much promise to measure particle concentrations in opaque, dispersed multiphase flows such as those encountered in plume-surface interactions. This study expands on a previously developed proof-of-concept millimeter-wave interferometer, demonstrating several mission-critical capabilities and providing unique insights in the ejecta dynamics of plume-surface interactions. An innovative vacuum calibration procedure reduced measurement uncertainties by one order of magnitude compared to prior calibrations at ambient conditions thanks to the reduction of aerodynamic entrainment. Calibration experiments verified the theoretical linear relation between phase shift and path-integrated particle number density and provided the constant proportionality factor for the specific glass microspheres and radar system employed. The instrument was demonstrated on a reduced-scale plume-surface interaction experiment. Ejecta path-integrated concentrations were measured at two ambient pressure levels representative of Lunar (14.26 Pa) and Martian (800 Pa) surface conditions, confirming the trends observed during prior experiments. Further experiments were conducted at 800 Pa to demonstrate the capability of the instrument to operate in very close proximity to the ground, and to analyze the distribution of ejecta with altitude. Ejecta path-integrated concentrations measured at 9, 6, and 3 cm above the granular surface provided maximum values of (1.284 ± 0.040) × 109 #.m−2 , (2.345 ± 0.051) × 109 #.m−2 , and (6.881 ± 1.659) × 109 #.m−2 respectively. Ongoing developments of millimeter-wave interferometry for concentration measurements aim at providing the 3D spatial distribution of ejecta cloud concentrations. To that end, a preliminary demonstration of 3D tomographic capabilities was performed using 3 reflectors, each defining a distinct measurement path. A tomographic reconstruction algorithm was implemented to convert path-integrated concentrations into standard concentrations, providing a maximum of (10.140 ± 0.442) × 109 #.m−3 measured at a radial distance of 8.8 cm from the nozzle axis.
UR - http://www.scopus.com/inward/record.url?scp=85198617214&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85198617214&partnerID=8YFLogxK
U2 - 10.2514/6.2023-0465
DO - 10.2514/6.2023-0465
M3 - Conference contribution
AN - SCOPUS:85198617214
SN - 9781624106996
T3 - AIAA SciTech Forum and Exposition, 2023
BT - AIAA SciTech Forum and Exposition, 2023
PB - American Institute of Aeronautics and Astronautics Inc, AIAA
T2 - AIAA SciTech Forum and Exposition, 2023
Y2 - 23 January 2023 through 27 January 2023
ER -