TY - JOUR
T1 - Simulations of submicron aerosol deposition at an air-liquid interface for in vitro toxicology
AU - Grabinski, Christin M.
AU - Hussain, Saber M.
AU - Mohan Sankaran, R.
N1 - Funding Information:
This work was funded by the Biosciences and Protection Division, Human Effectiveness Directorate, Air Force Research Laboratory under the Student Research Participation Program at the U.S. Air Force Research Laboratory administered by the Oak Ridge Institute for Science and Education (contract number 1264-1264-04) (to C.M.G.) and the U.S. Air Force Surgeon General (contract number FA8650-10-2-6062). We thank Prof. Harihara Baskaran at Case Western Reserve University for access to the COMSOL Multiphysics software package. R.M.S. acknowledges the AFOSR YIP Program under Award no. FA9550-10-1-0160 for also supporting this work.
Publisher Copyright:
© 2015 Elsevier Ltd.
PY - 2015/12/1
Y1 - 2015/12/1
N2 - Submicron particles released during the lifecycle of nano-enabled products and as a byproduct of air pollution and occupational processes are a potential health risk. Recent advancements to in vitro model systems have been proposed to assess the toxicity of particulate materials resulting from inhalation. The reliability of these models depends on the introduction and deposition of aerosolized particles on cells at an air-liquid interface. However, chamber geometry, gas flow rate, electric field, and other process parameters significantly impact how particles deposit at this interface. Here, we carried out finite element modeling to describe the transport and deposition of submicron aerosolized particles. Simulations were performed using multiphysics software on a typical in vitro exposure chamber design, and results were compared to analytical approximations for deposition efficiency. Deposition experiments were also systematically carried out to validate the modeling predictions. Our results show how deposition depends on various process parameters. To achieve efficient deposition without focusing, the electric field strength and gas flow rate must be balanced; at high gas flow rates, higher electric fields are required to achieve deposition. Further, we find that AC electric fields at the appropriate frequency can increase deposition above DC fields at similar strengths. Overall, the study establishes simulation approaches for the design of in vitro aerosol deposition chambers and relates key process parameters to deposition, which is critical to controlling the dose of submicron aerosols in in vitro toxicology experiments.
AB - Submicron particles released during the lifecycle of nano-enabled products and as a byproduct of air pollution and occupational processes are a potential health risk. Recent advancements to in vitro model systems have been proposed to assess the toxicity of particulate materials resulting from inhalation. The reliability of these models depends on the introduction and deposition of aerosolized particles on cells at an air-liquid interface. However, chamber geometry, gas flow rate, electric field, and other process parameters significantly impact how particles deposit at this interface. Here, we carried out finite element modeling to describe the transport and deposition of submicron aerosolized particles. Simulations were performed using multiphysics software on a typical in vitro exposure chamber design, and results were compared to analytical approximations for deposition efficiency. Deposition experiments were also systematically carried out to validate the modeling predictions. Our results show how deposition depends on various process parameters. To achieve efficient deposition without focusing, the electric field strength and gas flow rate must be balanced; at high gas flow rates, higher electric fields are required to achieve deposition. Further, we find that AC electric fields at the appropriate frequency can increase deposition above DC fields at similar strengths. Overall, the study establishes simulation approaches for the design of in vitro aerosol deposition chambers and relates key process parameters to deposition, which is critical to controlling the dose of submicron aerosols in in vitro toxicology experiments.
UR - http://www.scopus.com/inward/record.url?scp=84941277491&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84941277491&partnerID=8YFLogxK
U2 - 10.1016/j.jaerosci.2015.08.005
DO - 10.1016/j.jaerosci.2015.08.005
M3 - Comment/debate
AN - SCOPUS:84941277491
SN - 0021-8502
VL - 90
SP - 87
EP - 102
JO - Journal of Aerosol Science
JF - Journal of Aerosol Science
ER -