TY - JOUR
T1 - Sensitivity thresholds of groundwater parameters for detecting CO2 leakage at a geologic carbon sequestration site
AU - Berger, Peter M.
AU - Wimmer, Bracken
AU - Iranmanesh, Abbas
N1 - Funding Information:
This project is funded by the U.S. Department of Energy through the National Energy Technology Laboratory (NETL), under agreement DE-FE0031626.
Publisher Copyright:
© 2019, Springer Nature Switzerland AG.
Copyright:
Copyright 2019 Elsevier B.V., All rights reserved.
PY - 2019/11/1
Y1 - 2019/11/1
N2 - Geologic carbon sequestration (GCS) projects in the USA are required to monitor groundwater quality for geochemical changes above the injection area that may be a result of CO2 or brine leakage from the storage reservoir. Should CO2 migrate into the groundwater around the compliance wells monitoring the shallower hydrologic units, each compliance parameter could react differently depending on its sensitivity to CO2. Statistically determined limits (SDLs) for detection of CO2 leakage into groundwater were calculated using background water quality data from the Illinois Basin Decatur Project (IBDP) sequestration site and prediction and tolerance intervals for specific compliance parameters. If the parameter concentrations varied outside of these ranges during the injection and post injection periods of a GCS project, then additional actions would be required to determine the reason for the changes in groundwater concentrations. Geochemical modeling can simulate the amount of CO2 needed to alter water quality parameters a statistically significant amount. This information can then inform GCS operators and regulators as to which compliance parameters are relevant (sensitive) to CO2 leakage for a given setting. For the system studied in here, Fe, Ca, K, Mg, CO2, and pH were sensitive to CO2 addition while Al, Cl, Na, and Si were not.
AB - Geologic carbon sequestration (GCS) projects in the USA are required to monitor groundwater quality for geochemical changes above the injection area that may be a result of CO2 or brine leakage from the storage reservoir. Should CO2 migrate into the groundwater around the compliance wells monitoring the shallower hydrologic units, each compliance parameter could react differently depending on its sensitivity to CO2. Statistically determined limits (SDLs) for detection of CO2 leakage into groundwater were calculated using background water quality data from the Illinois Basin Decatur Project (IBDP) sequestration site and prediction and tolerance intervals for specific compliance parameters. If the parameter concentrations varied outside of these ranges during the injection and post injection periods of a GCS project, then additional actions would be required to determine the reason for the changes in groundwater concentrations. Geochemical modeling can simulate the amount of CO2 needed to alter water quality parameters a statistically significant amount. This information can then inform GCS operators and regulators as to which compliance parameters are relevant (sensitive) to CO2 leakage for a given setting. For the system studied in here, Fe, Ca, K, Mg, CO2, and pH were sensitive to CO2 addition while Al, Cl, Na, and Si were not.
KW - ISGS
KW - Statistical analysis
KW - Background data
KW - Carbon sequestration
KW - Geochemical modeling
UR - http://www.scopus.com/inward/record.url?scp=85074202373&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85074202373&partnerID=8YFLogxK
U2 - 10.1007/s10661-019-7880-7
DO - 10.1007/s10661-019-7880-7
M3 - Article
SN - 1573-2959
VL - 191
JO - Environmental Monitoring and Assessment
JF - Environmental Monitoring and Assessment
IS - 11
M1 - 685
ER -