T1 - Sensitivity Analysis of Reference-Free Quantitative Ultrasound Tissue Classification
AU - Nguyen, Trong
AU - Do, Minh
AU - Oelze, Michael L.
PY - 2018/12/17
Y1 - 2018/12/17
N2 - To implement spectral-based quantitative ultrasound (QUS), currently it is necessary to take a reference scan from a well-characterized tissue-mimicking material for each scanner setting that is used. The purpose of this study was to evaluate if a reference-free approach could be adopted, which would eliminate the need for multiple reference scans while still maintaining the ability to objectively classify different tissue states. Specifically, we utilized a convolutional neural network (CNN) to classify tissues and tissue-mimicking phantoms without taking a reference for each setting used and compared the performance to conventional QUS approaches using a reference phantom. Rabbits that were maintained on a high fat diet for 0, 1, 2, 3 or 6 weeks with five rabbits per diet group (total N = 30) were scanned ultrasonically and classified into two groups based on their liver lipid levels: low fat (8%) and high fat (> 8%). An array transducer L9-4 with center frequency of 4 MHz was used to gather RF backscattered data in vivo from the rabbits. In the conventional QUS approach the RF signals were calibrated from a reference phantom and used to estimate an average BSC for each rabbit. In the reference-free approach, a CNN was trained on the time domain RF signals to classify the rabbit livers. To assess the reliability of the CNN to classify when the settings of the scanner were adjusted, five tissue-mimicking phantoms with different but known properties were scanned under different system settings: power, time gain compensation and number of transmit foci. The CNN was first trained on one system setting and then tested on data acquired from each phantom with the other settings. This was repeated for each individual setting. The testing accuracy of in vivo rabbit liver classification using the CNN without a reference was 73% compared to 60% when using the conventional QUS. The results demonstrated that the CNN can provide accurate and robust classification without having to use a reference for each setting. This work was supported by a grant from the NIH (R21 EB020766).
AB - To implement spectral-based quantitative ultrasound (QUS), currently it is necessary to take a reference scan from a well-characterized tissue-mimicking material for each scanner setting that is used. The purpose of this study was to evaluate if a reference-free approach could be adopted, which would eliminate the need for multiple reference scans while still maintaining the ability to objectively classify different tissue states. Specifically, we utilized a convolutional neural network (CNN) to classify tissues and tissue-mimicking phantoms without taking a reference for each setting used and compared the performance to conventional QUS approaches using a reference phantom. Rabbits that were maintained on a high fat diet for 0, 1, 2, 3 or 6 weeks with five rabbits per diet group (total N = 30) were scanned ultrasonically and classified into two groups based on their liver lipid levels: low fat (8%) and high fat (> 8%). An array transducer L9-4 with center frequency of 4 MHz was used to gather RF backscattered data in vivo from the rabbits. In the conventional QUS approach the RF signals were calibrated from a reference phantom and used to estimate an average BSC for each rabbit. In the reference-free approach, a CNN was trained on the time domain RF signals to classify the rabbit livers. To assess the reliability of the CNN to classify when the settings of the scanner were adjusted, five tissue-mimicking phantoms with different but known properties were scanned under different system settings: power, time gain compensation and number of transmit foci. The CNN was first trained on one system setting and then tested on data acquired from each phantom with the other settings. This was repeated for each individual setting. The testing accuracy of in vivo rabbit liver classification using the CNN without a reference was 73% compared to 60% when using the conventional QUS. The results demonstrated that the CNN can provide accurate and robust classification without having to use a reference for each setting. This work was supported by a grant from the NIH (R21 EB020766).
KW - backscatter analysis
KW - convolutional neural networks
KW - quantitative ultrasound
UR - http://www.scopus.com/inward/record.url?scp=85060611310&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85060611310&partnerID=8YFLogxK
U2 - 10.1109/ULTSYM.2018.8579885
DO - 10.1109/ULTSYM.2018.8579885
M3 - Conference contribution
AN - SCOPUS:85060611310
T3 - IEEE International Ultrasonics Symposium, IUS
BT - 2018 IEEE International Ultrasonics Symposium, IUS 2018
PB - IEEE Computer Society
T2 - 2018 IEEE International Ultrasonics Symposium, IUS 2018
Y2 - 22 October 2018 through 25 October 2018
ER -