T1 - Reproducibility of Voice Parameters
T2 - The Effect of Room Acoustics and Microphones
AU - Bottalico, Pasquale
AU - Codino, Juliana
AU - Cantor-Cutiva, Lady Catherine
AU - Marks, Katherine
AU - Nudelman, Charles J.
AU - Skeffington, Jean
AU - Shrivastav, Rahul
AU - Jackson-Menaldi, Maria Cristina
AU - Hunter, Eric J.
AU - Rubin, Adam D.
N1 - Funding Information:
Funding: This research was funded by the National Institute on Deafness and other Communication Disorders of the National Institutes of Health under Award Number R01DC012315. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Publisher Copyright:
© 2018 The Voice Foundation
PY - 2020/5
Y1 - 2020/5
N2 - Introduction: Computer analysis of voice recordings is an integral part of the evaluation and management of voice disorders. In many practices, voice samples are taken in rooms that are not sound attenuated and/or sound-proofed; further, the technology used is rarely consistent. This will likely affect the recordings, and therefore, their analyses. Objectives: The objective of this study is to compare various acoustic outcome measures taken from samples recorded in a sound-proofed booth to those recorded in more common clinic environments. Further, the effects from six different commonly used microphones will be compared. Methods: Thirty-six speakers were recorded while reading a text and producing sustained vowels in a controlled acoustic environment. The collected samples were reproduced by a Head and Torso Simulator and recorded in three clinical rooms and in a sound booth using six different microphones. Newer measures (eg, Pitch Strength, cepstral peak prominence, Acoustic Voice Quality Index), as well as more traditional measures (eg Jitter, Shimmer, harmonics-to-noise ratio and Spectrum Tilt), were calculated from the samples collected with each microphone and within each room. Results: The measures which are more robust to room acoustic differences, background noise, and microphone quality include Jitter and smooth cepstral peak prominence, followed by Shimmer, Acoustic Voice Quality Index, harmonics-to-noise ratio, Pitch Strength, and Spectrum Tilt. Conclusions: The effect of room acoustics and background noise on voice parameters appears to be stronger than the type of microphone used for the recording. Consequently, an appropriate acoustical clinical space may be more important than the quality of the microphone.
AB - Introduction: Computer analysis of voice recordings is an integral part of the evaluation and management of voice disorders. In many practices, voice samples are taken in rooms that are not sound attenuated and/or sound-proofed; further, the technology used is rarely consistent. This will likely affect the recordings, and therefore, their analyses. Objectives: The objective of this study is to compare various acoustic outcome measures taken from samples recorded in a sound-proofed booth to those recorded in more common clinic environments. Further, the effects from six different commonly used microphones will be compared. Methods: Thirty-six speakers were recorded while reading a text and producing sustained vowels in a controlled acoustic environment. The collected samples were reproduced by a Head and Torso Simulator and recorded in three clinical rooms and in a sound booth using six different microphones. Newer measures (eg, Pitch Strength, cepstral peak prominence, Acoustic Voice Quality Index), as well as more traditional measures (eg Jitter, Shimmer, harmonics-to-noise ratio and Spectrum Tilt), were calculated from the samples collected with each microphone and within each room. Results: The measures which are more robust to room acoustic differences, background noise, and microphone quality include Jitter and smooth cepstral peak prominence, followed by Shimmer, Acoustic Voice Quality Index, harmonics-to-noise ratio, Pitch Strength, and Spectrum Tilt. Conclusions: The effect of room acoustics and background noise on voice parameters appears to be stronger than the type of microphone used for the recording. Consequently, an appropriate acoustical clinical space may be more important than the quality of the microphone.
KW - Acoustic analysis of voice–Room acoustics–Background noise–Microphone quality
UR - http://www.scopus.com/inward/record.url?scp=85056842075&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85056842075&partnerID=8YFLogxK
U2 - 10.1016/j.jvoice.2018.10.016
DO - 10.1016/j.jvoice.2018.10.016
M3 - Article
C2 - 30471944
AN - SCOPUS:85056842075
SN - 0892-1997
VL - 34
SP - 320
EP - 334
JO - Journal of Voice
JF - Journal of Voice
IS - 3
ER -