T1 - Rephasing Ion Packets in the Orbitrap Mass Analyzer to Improve Resolution and Peak Shape
AU - Perry, Richard H.
AU - Hu, Qizhi
AU - Salazar, Gary A.
AU - Cooks, R. Graham
AU - Noll, Robert J.
N1 - Funding Information:
The authors acknowledge the National Science Foundation MRI program 0216239-CHE and Office of Naval Research N00014 -05-0454 for support, as well as Jason S. Duncan for his expertise in electrical engineering.
PY - 2009/8
Y1 - 2009/8
N2 - A method is described to improve resolution and peak shape in the Orbitrap under certain experimental conditions. In these experiments, an asymmetric anharmonic axial potential was first produced in the Orbitrap by detuning the voltage on the compensator electrode, which results in broad and multiply split mass spectral peaks. An AC waveform applied to the outer electrode, 180° out of phase with ion axial motion and resonant with the frequency of ion axial motion, caused ions of a given m/z to be de-excited to the equator (z = 0) and then immediately re-excited. This process, termed "rephasing," leaves the ion packet with a narrower axial spatial extent and frequency distribution. For example, when the Orbitrap axial potential is thus anharmonically de-tuned, a resolution of 124,000 to 171,000 is obtained, a 2- to 3-fold improvement over the resolution of 40,000 to 60,000 without rephasing, at 10 ng/μL reserpine concentration. Such a rephasing capability may ultimately prove useful in implementing tandem mass spectrometry (MS/MS) in the Orbitrap, bringing the Orbitrap's high mass accuracy and resolution to bear on both the precursor and product ions in the same MS/MS scan and making available the collision energy regime of the Orbitrap, ∼1500 eV.
AB - A method is described to improve resolution and peak shape in the Orbitrap under certain experimental conditions. In these experiments, an asymmetric anharmonic axial potential was first produced in the Orbitrap by detuning the voltage on the compensator electrode, which results in broad and multiply split mass spectral peaks. An AC waveform applied to the outer electrode, 180° out of phase with ion axial motion and resonant with the frequency of ion axial motion, caused ions of a given m/z to be de-excited to the equator (z = 0) and then immediately re-excited. This process, termed "rephasing," leaves the ion packet with a narrower axial spatial extent and frequency distribution. For example, when the Orbitrap axial potential is thus anharmonically de-tuned, a resolution of 124,000 to 171,000 is obtained, a 2- to 3-fold improvement over the resolution of 40,000 to 60,000 without rephasing, at 10 ng/μL reserpine concentration. Such a rephasing capability may ultimately prove useful in implementing tandem mass spectrometry (MS/MS) in the Orbitrap, bringing the Orbitrap's high mass accuracy and resolution to bear on both the precursor and product ions in the same MS/MS scan and making available the collision energy regime of the Orbitrap, ∼1500 eV.
UR - http://www.scopus.com/inward/record.url?scp=67650763021&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=67650763021&partnerID=8YFLogxK
U2 - 10.1016/j.jasms.2009.02.011
DO - 10.1016/j.jasms.2009.02.011
M3 - Article
C2 - 19299166
AN - SCOPUS:67650763021
SN - 1044-0305
VL - 20
SP - 1397
EP - 1404
JO - Journal of the American Society for Mass Spectrometry
JF - Journal of the American Society for Mass Spectrometry
IS - 8
ER -