Psychometric properties of the 30-m walking test in patients with degenerative cervical myelopathy: results from two prospective multicenter cohort studies

Parker E. Bohm, Michael G. Fehlings, Branko Kopjar, Lindsay A. Tetreault, Alexander R. Vaccaro, Karen K. Anderson, Paul M. Arnold

Research output: Contribution to journalArticlepeer-review

Abstract

Background Context The timed 30-m walking test (30MWT) is used in clinical practice and in research to objectively quantify gait impairment. The psychometric properties of 30MWT have not yet been rigorously evaluated. Purpose This study aimed to determine test-retest reliability, divergent and convergent validity, and responsiveness to change of the 30MWT in patients with degenerative cervical myelopathy (DCM). Study Design/Setting A retrospective observational study was carried out. Patient Sample The sample consisted of patients with symptomatic DCM enrolled in the AOSpine North America or AOSpine International cervical spondylotic myelopathy studies at 26 sites. Outcome Measures Modified Japanese Orthopaedic Association scale (mJOA), Nurick scale, 30MWT, Neck Disability Index (NDI), and Short-Form-36 (SF-36v2) physical component score (PCS) and mental component score (MCS) were the outcome measures. Methods Data from two prospective multicenter cohort myelopathy studies were merged. Each patient was evaluated at baseline and 6 months postoperatively. Results Of 757 total patients, 682 (90.09%) attempted to perform the 30MWT at baseline. Of these 682 patients, 602 (88.12%) performed the 30MWT at baseline. One patient was excluded, leaving601 in the analysis. At baseline, 81 of 682 (11.88%) patients were unable to perform the test, and their mJOA, NDI, and SF-36v2 PCS scores were lower compared with those who performed the test at baseline. In patients who performed the 30MWT at baseline, there was very high correlation among the three baseline 30MWT measurements (r=0.9569–0.9919). The 30MWT demonstrated good convergent and divergent validity. It was moderately correlated with the Nurick (r=0.4932), mJOA (r=−0.4424), and SF-36v2 PCS (r=−0.3537) (convergent validity) and poorly correlated with the NDI (r=0.2107) and SF-36v2 MCS (r=−0.1984) (divergent validity). Overall, the 30MWT was not responsive to change (standardized response mean [SRM]=0.30). However, for patients who had a baseline time above the median value of 29 seconds, the SRM was 0.45. Conclusions The 30MWT shows high test-retest reliability and good divergent and convergent validity. It is responsive to change only in patients with more severe myelopathy. The 30MWT is a simple, quick, and affordable test, and should be used as an ancillary test to evaluate gait parameters in patients with DCM.

Original languageEnglish (US)
Pages (from-to)211-217
Number of pages7
JournalSpine Journal
Volume17
Issue number2
DOIs
StatePublished - Feb 1 2017
Externally publishedYes

Keywords

  • Gait impairment
  • Myelopathy, compressive
  • Psychometrics
  • Recovery of function
  • Reproducibility of results
  • Spondylosis, cervical
  • Stenosis, cervical
  • Task performance and analysis
  • Time factors
  • Treatment outcome

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine
  • Clinical Neurology

Fingerprint

Dive into the research topics of 'Psychometric properties of the 30-m walking test in patients with degenerative cervical myelopathy: results from two prospective multicenter cohort studies'. Together they form a unique fingerprint.

Cite this