TY - JOUR
T1 - Psychometric properties of the 30-m walking test in patients with degenerative cervical myelopathy
T2 - results from two prospective multicenter cohort studies
AU - Bohm, Parker E.
AU - Fehlings, Michael G.
AU - Kopjar, Branko
AU - Tetreault, Lindsay A.
AU - Vaccaro, Alexander R.
AU - Anderson, Karen K.
AU - Arnold, Paul M.
N1 - Publisher Copyright:
© 2016 Elsevier Inc.
PY - 2017/2/1
Y1 - 2017/2/1
N2 - Background Context The timed 30-m walking test (30MWT) is used in clinical practice and in research to objectively quantify gait impairment. The psychometric properties of 30MWT have not yet been rigorously evaluated. Purpose This study aimed to determine test-retest reliability, divergent and convergent validity, and responsiveness to change of the 30MWT in patients with degenerative cervical myelopathy (DCM). Study Design/Setting A retrospective observational study was carried out. Patient Sample The sample consisted of patients with symptomatic DCM enrolled in the AOSpine North America or AOSpine International cervical spondylotic myelopathy studies at 26 sites. Outcome Measures Modified Japanese Orthopaedic Association scale (mJOA), Nurick scale, 30MWT, Neck Disability Index (NDI), and Short-Form-36 (SF-36v2) physical component score (PCS) and mental component score (MCS) were the outcome measures. Methods Data from two prospective multicenter cohort myelopathy studies were merged. Each patient was evaluated at baseline and 6 months postoperatively. Results Of 757 total patients, 682 (90.09%) attempted to perform the 30MWT at baseline. Of these 682 patients, 602 (88.12%) performed the 30MWT at baseline. One patient was excluded, leaving601 in the analysis. At baseline, 81 of 682 (11.88%) patients were unable to perform the test, and their mJOA, NDI, and SF-36v2 PCS scores were lower compared with those who performed the test at baseline. In patients who performed the 30MWT at baseline, there was very high correlation among the three baseline 30MWT measurements (r=0.9569–0.9919). The 30MWT demonstrated good convergent and divergent validity. It was moderately correlated with the Nurick (r=0.4932), mJOA (r=−0.4424), and SF-36v2 PCS (r=−0.3537) (convergent validity) and poorly correlated with the NDI (r=0.2107) and SF-36v2 MCS (r=−0.1984) (divergent validity). Overall, the 30MWT was not responsive to change (standardized response mean [SRM]=0.30). However, for patients who had a baseline time above the median value of 29 seconds, the SRM was 0.45. Conclusions The 30MWT shows high test-retest reliability and good divergent and convergent validity. It is responsive to change only in patients with more severe myelopathy. The 30MWT is a simple, quick, and affordable test, and should be used as an ancillary test to evaluate gait parameters in patients with DCM.
AB - Background Context The timed 30-m walking test (30MWT) is used in clinical practice and in research to objectively quantify gait impairment. The psychometric properties of 30MWT have not yet been rigorously evaluated. Purpose This study aimed to determine test-retest reliability, divergent and convergent validity, and responsiveness to change of the 30MWT in patients with degenerative cervical myelopathy (DCM). Study Design/Setting A retrospective observational study was carried out. Patient Sample The sample consisted of patients with symptomatic DCM enrolled in the AOSpine North America or AOSpine International cervical spondylotic myelopathy studies at 26 sites. Outcome Measures Modified Japanese Orthopaedic Association scale (mJOA), Nurick scale, 30MWT, Neck Disability Index (NDI), and Short-Form-36 (SF-36v2) physical component score (PCS) and mental component score (MCS) were the outcome measures. Methods Data from two prospective multicenter cohort myelopathy studies were merged. Each patient was evaluated at baseline and 6 months postoperatively. Results Of 757 total patients, 682 (90.09%) attempted to perform the 30MWT at baseline. Of these 682 patients, 602 (88.12%) performed the 30MWT at baseline. One patient was excluded, leaving601 in the analysis. At baseline, 81 of 682 (11.88%) patients were unable to perform the test, and their mJOA, NDI, and SF-36v2 PCS scores were lower compared with those who performed the test at baseline. In patients who performed the 30MWT at baseline, there was very high correlation among the three baseline 30MWT measurements (r=0.9569–0.9919). The 30MWT demonstrated good convergent and divergent validity. It was moderately correlated with the Nurick (r=0.4932), mJOA (r=−0.4424), and SF-36v2 PCS (r=−0.3537) (convergent validity) and poorly correlated with the NDI (r=0.2107) and SF-36v2 MCS (r=−0.1984) (divergent validity). Overall, the 30MWT was not responsive to change (standardized response mean [SRM]=0.30). However, for patients who had a baseline time above the median value of 29 seconds, the SRM was 0.45. Conclusions The 30MWT shows high test-retest reliability and good divergent and convergent validity. It is responsive to change only in patients with more severe myelopathy. The 30MWT is a simple, quick, and affordable test, and should be used as an ancillary test to evaluate gait parameters in patients with DCM.
KW - Gait impairment
KW - Myelopathy, compressive
KW - Psychometrics
KW - Recovery of function
KW - Reproducibility of results
KW - Spondylosis, cervical
KW - Stenosis, cervical
KW - Task performance and analysis
KW - Time factors
KW - Treatment outcome
UR - http://www.scopus.com/inward/record.url?scp=85008601949&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85008601949&partnerID=8YFLogxK
U2 - 10.1016/j.spinee.2016.08.033
DO - 10.1016/j.spinee.2016.08.033
M3 - Article
C2 - 27592193
AN - SCOPUS:85008601949
SN - 1529-9430
VL - 17
SP - 211
EP - 217
JO - Spine Journal
JF - Spine Journal
IS - 2
ER -