Monitoring the hydrologic effects of an extensive green roof

Nathaniel Hanna Holloway, Charles J. Werth, Arthur R. Schmidt

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

A well known consequence of urbanization is an increase in impervious area (parking lots, streets, roofs, etc), which carries along with it a number of undesirable side effects; such as an increase in storm water runoff and often a degradation of downstream water quality. Storm water best management practices (BMP's) are currently being implemented in many communities across the United States to address these consequences. BMP's increase the pervious area in an urban environment and thus imitate natural storm water processes (i.e. infiltration, filtration, evaporation, etc). BMP's have been shown to reduce runoff quantity whilst improving runoff quality. One specific BMP, green roofs, are proposed to reduce storm water runoff through storage and improve water quality through filtration. While there are data that support these assertions, they are largely insufficient to describe the processes that produce the runoff and water quality changes. As a result, prediction of the hydrologic effects of green roofs (and other BMP's) over a range of conditions often relies on assumed adjustments to empirical parameters such as percent impervious or runoff curve number. In order to provide process-scale data describing hydrologic effects of green roofs, a monitoring system has been installed on an extensive green roof and an adjacent conventional roof on the new Business Instructional Facility on the University of Illinois Urbana-Champaign campus. The green roof being monitored is approximately 280 square meters with 0.20 meters of soil and a variety of sedums planted. The conventional roof is approximately 45 square meters. The green roof station is monitoring: volumetric water content at 15 locations, soil temperature at 9 locations, air temperature and relative humidity at two heights, rainfall, runoff, incoming and reflected solar radiation, and temperature underneath the roof at 5 locations. The conventional roof station is monitoring: roof surface temperature at two locations, air temperature and relative humidity at two heights, rainfall, horizontal wind velocity, runoff, incoming and reflected solar radiation, and temperature underneath the roof at 2 locations. In addition, automated samplers collect water quality samples from the runoff of both the green and conventional roofs and a passive atmospheric sampler monitors deposition of particles. To date atmospheric condition data and soil moisture and temperature data have been collected for 20 storm events.

Original languageEnglish (US)
Title of host publicationProceedings of World Environmental and Water Resources Congress 2009 - World Environmental and Water Resources Congress 2009
Subtitle of host publicationGreat Rivers
Pages1382-1399
Number of pages18
DOIs
StatePublished - 2009
EventWorld Environmental and Water Resources Congress 2009: Great Rivers - Kansas City, MO, United States
Duration: May 17 2009May 21 2009

Publication series

NameProceedings of World Environmental and Water Resources Congress 2009 - World Environmental and Water Resources Congress 2009: Great Rivers
Volume342

Other

OtherWorld Environmental and Water Resources Congress 2009: Great Rivers
Country/TerritoryUnited States
CityKansas City, MO
Period5/17/095/21/09

ASJC Scopus subject areas

  • General Environmental Science

Fingerprint

Dive into the research topics of 'Monitoring the hydrologic effects of an extensive green roof'. Together they form a unique fingerprint.

Cite this