TY - JOUR
T1 - Mitigation of artifacts due to isolated acoustic heterogeneities in photoacoustic computed tomography using a variable data truncation-based reconstruction method
AU - Poudel, Joemini
AU - Matthews, Thomas P.
AU - Li, Lei
AU - Anastasio, Mark A.
AU - Wang, Lihong V.
N1 - Funding Information:
This work was supported in part by National Institutes of Health award Nos. CA1744601, EB01696301, and 5T32EB01485505.
Publisher Copyright:
© 2017 Society of Photo-Optical Instrumentation Engineers (SPIE).
PY - 2017/4/1
Y1 - 2017/4/1
N2 - Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. If the object possesses spatially variant acoustic properties that are unaccounted for by the reconstruction method, the estimated image can contain distortions. While reconstruction methods have recently been developed to compensate for this effect, they generally require the object's acoustic properties to be known a priori. To circumvent the need for detailed information regarding an object's acoustic properties, we previously proposed a half-time reconstruction method for PACT. A half-time reconstruction method estimates the PACT image from a data set that has been temporally truncated to exclude the data components that have been strongly aberrated. However, this method can be improved upon when the approximate sizes and locations of isolated heterogeneous structures, such as bones or gas pockets, are known. To address this, we investigate PACT reconstruction methods that are based on a variable data truncation (VDT) approach. The VDT approach represents a generalization of the half-time approach, in which the degree of temporal truncation for each measurement is determined by the distance between the corresponding ultrasonic transducer location and the nearest known bone or gas void location. Computer-simulated and experimental data are employed to demonstrate the effectiveness of the approach in mitigating artifacts due to acoustic heterogeneities.
AB - Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. If the object possesses spatially variant acoustic properties that are unaccounted for by the reconstruction method, the estimated image can contain distortions. While reconstruction methods have recently been developed to compensate for this effect, they generally require the object's acoustic properties to be known a priori. To circumvent the need for detailed information regarding an object's acoustic properties, we previously proposed a half-time reconstruction method for PACT. A half-time reconstruction method estimates the PACT image from a data set that has been temporally truncated to exclude the data components that have been strongly aberrated. However, this method can be improved upon when the approximate sizes and locations of isolated heterogeneous structures, such as bones or gas pockets, are known. To address this, we investigate PACT reconstruction methods that are based on a variable data truncation (VDT) approach. The VDT approach represents a generalization of the half-time approach, in which the degree of temporal truncation for each measurement is determined by the distance between the corresponding ultrasonic transducer location and the nearest known bone or gas void location. Computer-simulated and experimental data are employed to demonstrate the effectiveness of the approach in mitigating artifacts due to acoustic heterogeneities.
KW - Image reconstruction
KW - Photoacoustic computed tomography
UR - http://www.scopus.com/inward/record.url?scp=85015810224&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85015810224&partnerID=8YFLogxK
U2 - 10.1117/1.JBO.22.4.041018
DO - 10.1117/1.JBO.22.4.041018
M3 - Article
C2 - 28267192
AN - SCOPUS:85015810224
SN - 1083-3668
VL - 22
JO - Journal of biomedical optics
JF - Journal of biomedical optics
IS - 4
M1 - 041018
ER -