Micro-interferometry for measurement of thermal displacements at fiber/matrix interfaces

N. R. Sottos, W. R. Scott, R. L. McCullough

Research output: Contribution to journalArticlepeer-review

Abstract

A micro-interferometric technique for measuring out-of-plane thermal displacements on a scale commensurate with the dimensions of the fiber/matrix unit cell is described. A scanning micro-interferometer is used to image surface displacements of samples containing a single-pitch-based carbon fiber embedded in an epoxy matrix. The interferometer design gives the necessary resolution to detect small changes in thermal displacements in the fiber/matrix interface region. The samples were heated electrically through the fiber to create radially symmetric temperature and displacement fields. Repeatable displacement measurements were obtained on a radial line across the interface region with an accuracy of ±25 Å. A sharp expansion of the matrix surrounding the fiber was observed with each heating. Overall, the experiments demonstrate the utility of micro-interferometry for measuring submicron displacements.

Original languageEnglish (US)
Pages (from-to)98-103
Number of pages6
JournalExperimental Mechanics
Volume31
Issue number2
DOIs
StatePublished - Jun 1991

ASJC Scopus subject areas

  • Aerospace Engineering
  • Mechanics of Materials
  • Mechanical Engineering

Fingerprint

Dive into the research topics of 'Micro-interferometry for measurement of thermal displacements at fiber/matrix interfaces'. Together they form a unique fingerprint.

Cite this