TY - GEN
T1 - Measurement uncertainties analysis in the determination of adiabatic film cooling effectiveness by using pressure sensitive paint (PSP) technique
AU - Johnson, Blake Everett
AU - Hu, Hui
N1 - Publisher Copyright:
Copyright © 2014 by ASME.
PY - 2014
Y1 - 2014
N2 - Pressure sensitive paint (PSP) is useful for measurements of wall pressure in high speed flows, but can be used in an alternative manner in low-speed flows as a gas species concentration detector. Film cooling technology studies have been greatly aided by this use of PSP through use of a mass transfer analogy to determine the adiabatic film cooling effectiveness. The PSP technique allows measurements that have high spatial resolution at high enough sampling rate that a good statistical mean can be determined rapidly. Due to the potential of this technique to deliver high quality adiabatic effectiveness measurements, a detailed analysis of its associated uncertainty is presented herein. In this study, an ambient temperature low speed wind tunnel drives air as the main flow while carbon dioxide (CO2, DR=1.5) is used as the "coolant" gas, though the experiments are done under isothermal conditions. A detailed analysis of the technique is performed here with focus on the measurement uncertainty and process uncertainty for a film cooling study using an array of five cylindrical holes spaced across the span of a flat test plate at a spacing of three diameters center-to-center. The final analysis indicates that the total uncertainty depends strongly on the local behavior of the coolant, with near-field uncertainty as high as 5% at isolated points. In the far-field, the total uncertainty is more uniform throughout the measurement domain and generally lower, at about 3%.
AB - Pressure sensitive paint (PSP) is useful for measurements of wall pressure in high speed flows, but can be used in an alternative manner in low-speed flows as a gas species concentration detector. Film cooling technology studies have been greatly aided by this use of PSP through use of a mass transfer analogy to determine the adiabatic film cooling effectiveness. The PSP technique allows measurements that have high spatial resolution at high enough sampling rate that a good statistical mean can be determined rapidly. Due to the potential of this technique to deliver high quality adiabatic effectiveness measurements, a detailed analysis of its associated uncertainty is presented herein. In this study, an ambient temperature low speed wind tunnel drives air as the main flow while carbon dioxide (CO2, DR=1.5) is used as the "coolant" gas, though the experiments are done under isothermal conditions. A detailed analysis of the technique is performed here with focus on the measurement uncertainty and process uncertainty for a film cooling study using an array of five cylindrical holes spaced across the span of a flat test plate at a spacing of three diameters center-to-center. The final analysis indicates that the total uncertainty depends strongly on the local behavior of the coolant, with near-field uncertainty as high as 5% at isolated points. In the far-field, the total uncertainty is more uniform throughout the measurement domain and generally lower, at about 3%.
UR - http://www.scopus.com/inward/record.url?scp=84919903947&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84919903947&partnerID=8YFLogxK
U2 - 10.1115/FEDSM2014-21230
DO - 10.1115/FEDSM2014-21230
M3 - Conference contribution
AN - SCOPUS:84919903947
T3 - American Society of Mechanical Engineers, Fluids Engineering Division (Publication) FEDSM
BT - Symposia
PB - American Society of Mechanical Engineers (ASME)
T2 - ASME 2014 4th Joint US-European Fluids Engineering Division Summer Meeting, FEDSM 2014, Collocated with the ASME 2014 12th International Conference on Nanochannels, Microchannels, and Minichannels
Y2 - 3 August 2014 through 7 August 2014
ER -