T1 - Lateral-flow enzyme immunoconcentration for rapid detection of Listeria monocytogenes
AU - Cho, Il Hoon
AU - Irudayaraj, Joseph
N1 - Funding Information:
Acknowledgment This work was supported by funding from the Center for Food Safety Engineering through a collaborative grant between USDA-ARS and Purdue University.
PY - 2013/4
Y1 - 2013/4
N2 - Lateral-flow enzyme immunochromatography coupled with an immunomagnetic step was developed for rapid detection of Listeria monocytogenes in food matrices. The target bacteria was first separated and concentrated by magnetic nanoparticles containing the enzyme and directly applied to the assay system to induce an antigen-antibody reaction without any additional steps. The color signals produced by an enzyme-substrate reaction at a specific site on the immunostrip were found to be directly proportional to the concentration of L. monocytogenes in the sample. The detection concept was demonstrated by performing an enzyme immunoassay on a microtiter well prior to applying it to the lateral-flow assay. Results of the chromatographic analysis yield a limit of detection of 95 and 97 ± 19.5 CFU/mL in buffer solution and 2 % milk sample, respectively. In addition to the high sensitivity, it was also possible to shorten the separation and detection time to within 2 h. The system also showed no cross-reactivity with other bacteria (e.g., Escherichia coli O157:H7, Salmonella typhimurium, and Salmonella enteritidis). The analytical procedure developed will enable us to not only utilize the assay in the field where fast screening for pathogenic agents is required but also as a preventive measure to contain disease outbreak.
AB - Lateral-flow enzyme immunochromatography coupled with an immunomagnetic step was developed for rapid detection of Listeria monocytogenes in food matrices. The target bacteria was first separated and concentrated by magnetic nanoparticles containing the enzyme and directly applied to the assay system to induce an antigen-antibody reaction without any additional steps. The color signals produced by an enzyme-substrate reaction at a specific site on the immunostrip were found to be directly proportional to the concentration of L. monocytogenes in the sample. The detection concept was demonstrated by performing an enzyme immunoassay on a microtiter well prior to applying it to the lateral-flow assay. Results of the chromatographic analysis yield a limit of detection of 95 and 97 ± 19.5 CFU/mL in buffer solution and 2 % milk sample, respectively. In addition to the high sensitivity, it was also possible to shorten the separation and detection time to within 2 h. The system also showed no cross-reactivity with other bacteria (e.g., Escherichia coli O157:H7, Salmonella typhimurium, and Salmonella enteritidis). The analytical procedure developed will enable us to not only utilize the assay in the field where fast screening for pathogenic agents is required but also as a preventive measure to contain disease outbreak.
KW - Enzyme immunoassay
KW - Immunochromatography
KW - Immunomagnetic concentration
KW - Lateral flow
KW - Listeria monocytogenes
KW - Signal enhancement
UR - http://www.scopus.com/inward/record.url?scp=84876144379&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84876144379&partnerID=8YFLogxK
U2 - 10.1007/s00216-013-6742-3
DO - 10.1007/s00216-013-6742-3
M3 - Article
C2 - 23354582
AN - SCOPUS:84876144379
SN - 1618-2642
VL - 405
SP - 3313
EP - 3319
JO - Analytical and bioanalytical chemistry
JF - Analytical and bioanalytical chemistry
IS - 10
ER -