TY - JOUR
T1 - Intra- and inter-rater reliability of muscle and fat thickness measurements obtained using portable ultrasonography in older adults
AU - Benatti de Oliveira, Gabriela
AU - Vilar Fernandes, Lara
AU - Summer Chen, Xiayu
AU - Drumond Andrade, Flavia Cristina
AU - Scarlazzari Costa, Luciana
AU - Junqueira Vasques, Ana Carolina
AU - Pires Corona, Ligiana
N1 - This work was supported by Coordination for the Improvement of Higher Education Personnel - Brazil (Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES) [Finance Code 001 and 88887.695788/2022-00] –and by São Paulo Research Foundation (FAPESP) [Finance Code 2020/00944-2], and the Lemann Center for Brazilian Studies and the National Council for Scientific Development (CNPQ – Conselho Nacional de Desenvolvimento Científico e Tecnológico) [productivity grant 304838/2022-5].
PY - 2024/4
Y1 - 2024/4
N2 - Background & aims: Ultrasonography (US) is a promising tool for assessing body composition, offering accuracy and accessibility. However, technician skills and equipment characteristics can impact measurement reliability. We aimed to evaluate the intra- and inter-rater reliability of two evaluators using A-mode Portable Ultrasound to measure muscle and fat thickness in Brazilian older adults. Methods: Quantitative cross-sectional study carried out with 150 community-dwelling older adults of Campinas-SP-Brazil, recruited in a retirement preparation program and a geriatric outpatient care unit. Scans of nine anatomical points were performed using the portable ultrasound in A-mode (BodyMetrix Pro System BX2000; Livermore, CA), with 6 scans per location and 3 measurements taken by each evaluator. After the selection and analysis of the generated images, muscle and fat thickness were measured. Reliability estimates between measures of the same evaluator (intra-rater) and between evaluators (inter-rater) were assessed using intraclass correlation coefficients (ICC), and differences within and between technicians were assessed using one-way ANOVA. Analyses were carried out for the overall sample and stratified by sex and by nutritional status. Results: Excellent ICC values (>0.90) were found for subcutaneous fat thickness in intra- and inter-rater reliability analyses. The lowest ICC values were observed for deep abdominal fat thickness measured by evaluator 1 (ICC = 0.90) and evaluator 2 (ICC = 0.87), as well as in the inter-rater analysis (ICC = 0.85). Muscle thickness measurements had satisfactory ICC values for triceps, biceps, anterior thigh, and calf, ranging from moderate to good (ICC 0.50–0.90). Conclusion: A portable A-mode ultrasound demonstrates excellent reliability among both intra- and inter-raters for assessing fat thickness but only moderate for muscle thickness in older adults. Hence, this could prompt inquiries regarding the sole reliance on this tool for quantifying muscle mass and examining sarcopenia in older adults. To our knowledge, this study represents the first assessment of reliability for a portable A-mode ultrasound device conducted with older adults.
AB - Background & aims: Ultrasonography (US) is a promising tool for assessing body composition, offering accuracy and accessibility. However, technician skills and equipment characteristics can impact measurement reliability. We aimed to evaluate the intra- and inter-rater reliability of two evaluators using A-mode Portable Ultrasound to measure muscle and fat thickness in Brazilian older adults. Methods: Quantitative cross-sectional study carried out with 150 community-dwelling older adults of Campinas-SP-Brazil, recruited in a retirement preparation program and a geriatric outpatient care unit. Scans of nine anatomical points were performed using the portable ultrasound in A-mode (BodyMetrix Pro System BX2000; Livermore, CA), with 6 scans per location and 3 measurements taken by each evaluator. After the selection and analysis of the generated images, muscle and fat thickness were measured. Reliability estimates between measures of the same evaluator (intra-rater) and between evaluators (inter-rater) were assessed using intraclass correlation coefficients (ICC), and differences within and between technicians were assessed using one-way ANOVA. Analyses were carried out for the overall sample and stratified by sex and by nutritional status. Results: Excellent ICC values (>0.90) were found for subcutaneous fat thickness in intra- and inter-rater reliability analyses. The lowest ICC values were observed for deep abdominal fat thickness measured by evaluator 1 (ICC = 0.90) and evaluator 2 (ICC = 0.87), as well as in the inter-rater analysis (ICC = 0.85). Muscle thickness measurements had satisfactory ICC values for triceps, biceps, anterior thigh, and calf, ranging from moderate to good (ICC 0.50–0.90). Conclusion: A portable A-mode ultrasound demonstrates excellent reliability among both intra- and inter-raters for assessing fat thickness but only moderate for muscle thickness in older adults. Hence, this could prompt inquiries regarding the sole reliance on this tool for quantifying muscle mass and examining sarcopenia in older adults. To our knowledge, this study represents the first assessment of reliability for a portable A-mode ultrasound device conducted with older adults.
KW - Body composition
KW - Fat thickness
KW - Intraclass correlation coefficients
KW - Muscle thickness
KW - Nutritional assessment
UR - http://www.scopus.com/inward/record.url?scp=85182726370&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85182726370&partnerID=8YFLogxK
U2 - 10.1016/j.clnesp.2024.01.005
DO - 10.1016/j.clnesp.2024.01.005
M3 - Article
C2 - 38479941
AN - SCOPUS:85182726370
SN - 2405-4577
VL - 60
SP - 65
EP - 72
JO - Clinical Nutrition ESPEN
JF - Clinical Nutrition ESPEN
ER -