INDUCTION ELECTRODYNAMIC PUMP IN A VERTICAL CONFIGURATION - II: EXPERIMENTAL STUDY.

J. Seyed-Yagoobi, J. C. Chato, J. M. Crowley, P. T. Krein

Research output: Contribution to journalConference articlepeer-review

Abstract

For Pt. I, see ibid. , pp. 1567-1573. An induction electrohydrodynamic (EHD) pump in axisymmetric, vertical configuration was designed and built. The flow rates were measured for various values of the frequency, voltage, wavelength, electric conductivity, and entrance temperature profile in both forward and backward modes. With the apparatus at relatively low voltages, velocities four times higher than the natural circulation velocity are obtained. The external pressure load and entrance temperature profile play an important role in the operation of the pump and must be considered in the design.

Original languageEnglish (US)
Pages (from-to)1574-1579
Number of pages6
JournalConference Record - IAS Annual Meeting (IEEE Industry Applications Society)
StatePublished - 1985
Externally publishedYes

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'INDUCTION ELECTRODYNAMIC PUMP IN A VERTICAL CONFIGURATION - II: EXPERIMENTAL STUDY.'. Together they form a unique fingerprint.