Implementation of a radiant heating and cooling model into an integrated building energy analysis program

Richard Karl Strand, Curtis O. Pedersen

Research output: Contribution to journalArticle

Abstract

The ability to fairly compare the energy efficiency of radiant heating and cooling systems to conventional forced-air systems has been a long-standing goal of the engineering design community. Such a comparison can only be made, however, through the fundamental analysis of the transient nature of the radiant system, the combined radiative and convective heat transfer from the radiant system, and the resulting thermal environment produced by both space-conditioning systems. A simulation tool that incorporates all of these characteristics has been developed. The model uses a derivative of conduction transfer functions that includes the effects of embedded sources or sinks to accurately account for the transient heat conduction in the radiant system. This model has been implemented into a well-known heat-balance-based energy analysis program and takes into account both the radiative and convective heat transfer at the surface of the radiant system. Due to the fact that the energy analysis program has three established thermal comfort models built into it, it is possible to compare energy consumption on the basis of resulting thermal comfort parameters rather than simply mean air temperature. Additionally, since interior surface temperatures are readily available, the model can evaluate radiant cooling systems for condensation potential and thus can be used to indicate when a hybrid system is needed. This paper describes the implementation of the radiant heating and cooling model and presents an example comparing the energy consumption of a radiant system and a conventional forced-air system that provide equal levels of comfort.

Original languageEnglish (US)
Pages (from-to)949-958
Number of pages10
JournalASHRAE Transactions
Volume103
Issue number1
StatePublished - 1997

Fingerprint

Radiant heating
Cooling
Thermal comfort
Cooling systems
Energy utilization
Air
Heat transfer
Hybrid systems
Heat conduction
Transfer functions
Energy efficiency
Condensation
Derivatives
Temperature

ASJC Scopus subject areas

  • Fluid Flow and Transfer Processes

Cite this

Implementation of a radiant heating and cooling model into an integrated building energy analysis program. / Strand, Richard Karl; Pedersen, Curtis O.

In: ASHRAE Transactions, Vol. 103, No. 1, 1997, p. 949-958.

Research output: Contribution to journalArticle

@article{506fdabf3e1d432d90bbeec9060609f2,
title = "Implementation of a radiant heating and cooling model into an integrated building energy analysis program",
abstract = "The ability to fairly compare the energy efficiency of radiant heating and cooling systems to conventional forced-air systems has been a long-standing goal of the engineering design community. Such a comparison can only be made, however, through the fundamental analysis of the transient nature of the radiant system, the combined radiative and convective heat transfer from the radiant system, and the resulting thermal environment produced by both space-conditioning systems. A simulation tool that incorporates all of these characteristics has been developed. The model uses a derivative of conduction transfer functions that includes the effects of embedded sources or sinks to accurately account for the transient heat conduction in the radiant system. This model has been implemented into a well-known heat-balance-based energy analysis program and takes into account both the radiative and convective heat transfer at the surface of the radiant system. Due to the fact that the energy analysis program has three established thermal comfort models built into it, it is possible to compare energy consumption on the basis of resulting thermal comfort parameters rather than simply mean air temperature. Additionally, since interior surface temperatures are readily available, the model can evaluate radiant cooling systems for condensation potential and thus can be used to indicate when a hybrid system is needed. This paper describes the implementation of the radiant heating and cooling model and presents an example comparing the energy consumption of a radiant system and a conventional forced-air system that provide equal levels of comfort.",
author = "Strand, {Richard Karl} and Pedersen, {Curtis O.}",
year = "1997",
language = "English (US)",
volume = "103",
pages = "949--958",
journal = "ASHRAE Transactions",
issn = "0001-2505",
publisher = "Amer. Soc. Heating, Ref. Air-Conditoning Eng. Inc.",
number = "1",

}

TY - JOUR

T1 - Implementation of a radiant heating and cooling model into an integrated building energy analysis program

AU - Strand, Richard Karl

AU - Pedersen, Curtis O.

PY - 1997

Y1 - 1997

N2 - The ability to fairly compare the energy efficiency of radiant heating and cooling systems to conventional forced-air systems has been a long-standing goal of the engineering design community. Such a comparison can only be made, however, through the fundamental analysis of the transient nature of the radiant system, the combined radiative and convective heat transfer from the radiant system, and the resulting thermal environment produced by both space-conditioning systems. A simulation tool that incorporates all of these characteristics has been developed. The model uses a derivative of conduction transfer functions that includes the effects of embedded sources or sinks to accurately account for the transient heat conduction in the radiant system. This model has been implemented into a well-known heat-balance-based energy analysis program and takes into account both the radiative and convective heat transfer at the surface of the radiant system. Due to the fact that the energy analysis program has three established thermal comfort models built into it, it is possible to compare energy consumption on the basis of resulting thermal comfort parameters rather than simply mean air temperature. Additionally, since interior surface temperatures are readily available, the model can evaluate radiant cooling systems for condensation potential and thus can be used to indicate when a hybrid system is needed. This paper describes the implementation of the radiant heating and cooling model and presents an example comparing the energy consumption of a radiant system and a conventional forced-air system that provide equal levels of comfort.

AB - The ability to fairly compare the energy efficiency of radiant heating and cooling systems to conventional forced-air systems has been a long-standing goal of the engineering design community. Such a comparison can only be made, however, through the fundamental analysis of the transient nature of the radiant system, the combined radiative and convective heat transfer from the radiant system, and the resulting thermal environment produced by both space-conditioning systems. A simulation tool that incorporates all of these characteristics has been developed. The model uses a derivative of conduction transfer functions that includes the effects of embedded sources or sinks to accurately account for the transient heat conduction in the radiant system. This model has been implemented into a well-known heat-balance-based energy analysis program and takes into account both the radiative and convective heat transfer at the surface of the radiant system. Due to the fact that the energy analysis program has three established thermal comfort models built into it, it is possible to compare energy consumption on the basis of resulting thermal comfort parameters rather than simply mean air temperature. Additionally, since interior surface temperatures are readily available, the model can evaluate radiant cooling systems for condensation potential and thus can be used to indicate when a hybrid system is needed. This paper describes the implementation of the radiant heating and cooling model and presents an example comparing the energy consumption of a radiant system and a conventional forced-air system that provide equal levels of comfort.

UR - http://www.scopus.com/inward/record.url?scp=0030647631&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030647631&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0030647631

VL - 103

SP - 949

EP - 958

JO - ASHRAE Transactions

JF - ASHRAE Transactions

SN - 0001-2505

IS - 1

ER -