Skip to main navigation Skip to search Skip to main content

Impact of sirolimus-eluting stents on outcome in diabetic patients: A SIRIUS (SIRolImUS-coated Bx velocity balloon-expandable stent in the treatmeat of patients with de novo coronary artery lesions) substudy

  • Issam Moussa
  • , Martin B. Leon
  • , Donald S. Baim
  • , William W. O'Neill
  • , Jeffery J. Popma
  • , Maurice Buchbinder
  • , Jay Midwall
  • , Charles A. Simonton
  • , Emily Keim
  • , Patrick Wang
  • , Richard E. Kuntz
  • , Jeffrey W. Moses

Research output: Contribution to journalArticlepeer-review

Abstract

Background - Randomized clinical trials have shown that a sirolimus-eluting stent significantly reduces restenosis after percutaneous coronary revascularization. Diabetic patients are known to have a higher risk of restenosis compared with nondiabetic patients. The purpose of this analysis was to determine the impact of sirolimus-eluting stents on outcomes of diabetic compared with nondiabetic patients. Methods and Results - The SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) trial is a randomized, double-blind study that compared sirolimus-eluting and bare metal stent implantation in 1058 patients with de novo native coronary artery lesions. Diabetes mellitus was present in 279 (26%) patients (diabetes mellitus group, 131 patients received sirolimus-eluting stents and 148 patients received bare metal stents) and was absent in 778 patients (no-diabetes mellitus group, 402 patients received sirolimus-eluting stents and 376 patients received bare metal stents). At 270 days, target lesion revascularization was reduced in diabetic patients from 22.3% with bare metal stents to 6.9% with sirolimus-eluting stents (P<0.001) and in nondiabetic patients from 14.1% to 2.99% (P<0.001), respectively. Major adverse cardiac events were reduced in diabetic patients from 25% with bare metal stents to 9.2% with sirolimus-eluting stents (P<0.001) and from 16.5% to 6.5% (P<0.001) in nondiabetic patients, respectively. Conclusions - Implantation of sirolimus-eluting stents compared with bare metal stents in de novo coronary lesions reduces major adverse cardiac events in patients with and without diabetes mellitus. However, among patients receiving sirolimus-eluting stents, there remains a trend toward a higher frequency of repeat intervention in diabetic patients compared with nondiabetic patients, particularly in the insulin-requiring patients.

Original languageEnglish (US)
Pages (from-to)2273-2278
Number of pages6
JournalCirculation
Volume109
Issue number19
DOIs
StatePublished - May 18 2004
Externally publishedYes

Keywords

  • Diabetes mellitus
  • Restenosis
  • Stents

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Fingerprint

Dive into the research topics of 'Impact of sirolimus-eluting stents on outcome in diabetic patients: A SIRIUS (SIRolImUS-coated Bx velocity balloon-expandable stent in the treatmeat of patients with de novo coronary artery lesions) substudy'. Together they form a unique fingerprint.

Cite this