Abstract
The effectiveness of delta-wing type vortex generators is experimentally evaluated by full-scale wind-tunnel testing of a compact heat exchanger typical to those used in automotive systems. The mechanisms important to vortex enhancement methods are discussed, and a basis for selecting a delta-wing design as a vortex generator is established. The heat transfer and pressure drop performance are assessed at full scale under both dry- and wet-surface conditions for a louvered-fin baseline and for a vortex-enhanced louvered-fin heat exchanger. An average heat transfer increase over the baseline case of 21% for dry conditions and 23.4% for wet conditions was achieved with a pressure drop penalty smaller than 7%. Vortex generation is proven to provide an improved thermal-hydraulic performance in compact heat exchangers for automotive systems.
Original language | English (US) |
---|---|
Pages (from-to) | 1480-1493 |
Number of pages | 14 |
Journal | International Journal of Heat and Mass Transfer |
Volume | 48 |
Issue number | 8 |
DOIs | |
State | Published - Apr 2005 |
ASJC Scopus subject areas
- Condensed Matter Physics
- Mechanical Engineering
- Fluid Flow and Transfer Processes