T1 - High-Resolution dual-trap optical tweezers with differential detection
T2 - Alignment of instrument components
AU - Bustamante, Carlos
AU - Chemla, Yann R.
AU - Moffitt, Jeffrey R.
PY - 2009
Y1 - 2009
N2 - Optical traps or "optical tweezers" have become an indispensable tool in understanding fundamental biological processes. Using our design, a dual-trap optical tweezers with differential detection, we can detect length changes to a DNA molecule tethering the trapped beads of 1 bp. By forming two traps from the same laser and maximizing the common optical paths of the two trapping beams, we decouple the instrument from many sources of environmental and instrumental noise that typically limit spatial resolution. The performance of a high-resolution instrument - the formation of strong traps, the minimization of background signals from trap movements, or the mitigation of the axial coupling, for example - can be greatly improved through careful alignment. This procedure, which is described in this article, starts from the laser and advances through the instrument, component by component. Alignment is complicated by the fact that the trapping light is in the near infrared (NIR) spectrum. Standard infrared viewing cards are commonly used to locate the beam, but unfortunately, bleach quickly. As an alternative, we use an IR-viewing charge-coupled device (CCD) camera equipped with a C-mount telephoto lens and display its image on a monitor. By visualizing the scattered light on a pair of irises of identical height separated by >12 in., the beam direction can be set very accurately along a fixed axis.
AB - Optical traps or "optical tweezers" have become an indispensable tool in understanding fundamental biological processes. Using our design, a dual-trap optical tweezers with differential detection, we can detect length changes to a DNA molecule tethering the trapped beads of 1 bp. By forming two traps from the same laser and maximizing the common optical paths of the two trapping beams, we decouple the instrument from many sources of environmental and instrumental noise that typically limit spatial resolution. The performance of a high-resolution instrument - the formation of strong traps, the minimization of background signals from trap movements, or the mitigation of the axial coupling, for example - can be greatly improved through careful alignment. This procedure, which is described in this article, starts from the laser and advances through the instrument, component by component. Alignment is complicated by the fact that the trapping light is in the near infrared (NIR) spectrum. Standard infrared viewing cards are commonly used to locate the beam, but unfortunately, bleach quickly. As an alternative, we use an IR-viewing charge-coupled device (CCD) camera equipped with a C-mount telephoto lens and display its image on a monitor. By visualizing the scattered light on a pair of irises of identical height separated by >12 in., the beam direction can be set very accurately along a fixed axis.
UR - http://www.scopus.com/inward/record.url?scp=70949097006&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=70949097006&partnerID=8YFLogxK
U2 - 10.1101/pdb.ip76
DO - 10.1101/pdb.ip76
M3 - Article
C2 - 20147041
AN - SCOPUS:70949097006
SN - 1559-6095
VL - 4
JO - Cold Spring Harbor Protocols
JF - Cold Spring Harbor Protocols
IS - 10
ER -