Godunov-type solutions for transient flows in sewers

Arturo S. León, Mohamed S. Ghidaoui, Arthur R. Schmidt, Marcelo H. García

Research output: Contribution to journalArticle

Abstract

This work is part of a long term project which aims at developing a hydraulic model for real-time simulation of unsteady flows in sewers ranging from gravity flows, to partly gravity-partly surcharged flows to fully surcharged flows. The success of this project hinges on the ability of the hydraulic model to handle a wide range of complex boundaries and to provide accurate solutions with the least central processing unit time. This first paper focuses on the development and assessment of two second-order explicit finite-volume Godunov-type schemes (GTS) for unsteady gravity flows in sewers, but with no surcharging. Traditionally, hydraulic transients have been modeled using the method of characteristics (MOC), which is noted for its ability to handle complex boundary conditions (BCs). The two GTS described herein incorporate BCs in a similar manner to the MOC. The accuracy and efficiency of these GTS schemes are investigated using problems whose solution contains features that are relevant to transient flows in sewers such as shock, expansion, and roll waves. The results show that these GTS schemes are significantly faster to execute than the fixed-grid MOC scheme with space-line interpolation, and in some cases, the accuracy produced by the two GTS schemes cannot be matched by the accuracy of the MOC scheme, even when a Courant number close to one and a large number of grids is used. Furthermore, unlike the MOC solutions, which exhibit increasing numerical dissipation with decreasing Courant numbers, the resolution of the shock fronts was maintained by the GTS schemes even for very low Courant numbers (0.001).

Original languageEnglish (US)
Pages (from-to)800-813
Number of pages14
JournalJournal of Hydraulic Engineering
Volume132
Issue number8
DOIs
StatePublished - Aug 1 2006

Fingerprint

transient flow
Sewers
Gravitation
Hydraulic models
Boundary conditions
gravity flow
unsteady flow
hydraulics
Hinges
Unsteady flow
boundary condition
solution feature
Program processors
Interpolation
Hydraulics
interpolation
dissipation
method
gravity
simulation

Keywords

  • Hydraulic models
  • Sewers
  • Transient flow

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Water Science and Technology
  • Mechanical Engineering

Cite this

Godunov-type solutions for transient flows in sewers. / León, Arturo S.; Ghidaoui, Mohamed S.; Schmidt, Arthur R.; García, Marcelo H.

In: Journal of Hydraulic Engineering, Vol. 132, No. 8, 01.08.2006, p. 800-813.

Research output: Contribution to journalArticle

León, Arturo S. ; Ghidaoui, Mohamed S. ; Schmidt, Arthur R. ; García, Marcelo H. / Godunov-type solutions for transient flows in sewers. In: Journal of Hydraulic Engineering. 2006 ; Vol. 132, No. 8. pp. 800-813.
@article{df13af0df7b24734950201cc4af5c71a,
title = "Godunov-type solutions for transient flows in sewers",
abstract = "This work is part of a long term project which aims at developing a hydraulic model for real-time simulation of unsteady flows in sewers ranging from gravity flows, to partly gravity-partly surcharged flows to fully surcharged flows. The success of this project hinges on the ability of the hydraulic model to handle a wide range of complex boundaries and to provide accurate solutions with the least central processing unit time. This first paper focuses on the development and assessment of two second-order explicit finite-volume Godunov-type schemes (GTS) for unsteady gravity flows in sewers, but with no surcharging. Traditionally, hydraulic transients have been modeled using the method of characteristics (MOC), which is noted for its ability to handle complex boundary conditions (BCs). The two GTS described herein incorporate BCs in a similar manner to the MOC. The accuracy and efficiency of these GTS schemes are investigated using problems whose solution contains features that are relevant to transient flows in sewers such as shock, expansion, and roll waves. The results show that these GTS schemes are significantly faster to execute than the fixed-grid MOC scheme with space-line interpolation, and in some cases, the accuracy produced by the two GTS schemes cannot be matched by the accuracy of the MOC scheme, even when a Courant number close to one and a large number of grids is used. Furthermore, unlike the MOC solutions, which exhibit increasing numerical dissipation with decreasing Courant numbers, the resolution of the shock fronts was maintained by the GTS schemes even for very low Courant numbers (0.001).",
keywords = "Hydraulic models, Sewers, Transient flow",
author = "Le{\'o}n, {Arturo S.} and Ghidaoui, {Mohamed S.} and Schmidt, {Arthur R.} and Garc{\'i}a, {Marcelo H.}",
year = "2006",
month = "8",
day = "1",
doi = "10.1061/(ASCE)0733-9429(2006)132:8(800)",
language = "English (US)",
volume = "132",
pages = "800--813",
journal = "Journal of Hydraulic Engineering",
issn = "0733-9429",
publisher = "American Society of Civil Engineers (ASCE)",
number = "8",

}

TY - JOUR

T1 - Godunov-type solutions for transient flows in sewers

AU - León, Arturo S.

AU - Ghidaoui, Mohamed S.

AU - Schmidt, Arthur R.

AU - García, Marcelo H.

PY - 2006/8/1

Y1 - 2006/8/1

N2 - This work is part of a long term project which aims at developing a hydraulic model for real-time simulation of unsteady flows in sewers ranging from gravity flows, to partly gravity-partly surcharged flows to fully surcharged flows. The success of this project hinges on the ability of the hydraulic model to handle a wide range of complex boundaries and to provide accurate solutions with the least central processing unit time. This first paper focuses on the development and assessment of two second-order explicit finite-volume Godunov-type schemes (GTS) for unsteady gravity flows in sewers, but with no surcharging. Traditionally, hydraulic transients have been modeled using the method of characteristics (MOC), which is noted for its ability to handle complex boundary conditions (BCs). The two GTS described herein incorporate BCs in a similar manner to the MOC. The accuracy and efficiency of these GTS schemes are investigated using problems whose solution contains features that are relevant to transient flows in sewers such as shock, expansion, and roll waves. The results show that these GTS schemes are significantly faster to execute than the fixed-grid MOC scheme with space-line interpolation, and in some cases, the accuracy produced by the two GTS schemes cannot be matched by the accuracy of the MOC scheme, even when a Courant number close to one and a large number of grids is used. Furthermore, unlike the MOC solutions, which exhibit increasing numerical dissipation with decreasing Courant numbers, the resolution of the shock fronts was maintained by the GTS schemes even for very low Courant numbers (0.001).

AB - This work is part of a long term project which aims at developing a hydraulic model for real-time simulation of unsteady flows in sewers ranging from gravity flows, to partly gravity-partly surcharged flows to fully surcharged flows. The success of this project hinges on the ability of the hydraulic model to handle a wide range of complex boundaries and to provide accurate solutions with the least central processing unit time. This first paper focuses on the development and assessment of two second-order explicit finite-volume Godunov-type schemes (GTS) for unsteady gravity flows in sewers, but with no surcharging. Traditionally, hydraulic transients have been modeled using the method of characteristics (MOC), which is noted for its ability to handle complex boundary conditions (BCs). The two GTS described herein incorporate BCs in a similar manner to the MOC. The accuracy and efficiency of these GTS schemes are investigated using problems whose solution contains features that are relevant to transient flows in sewers such as shock, expansion, and roll waves. The results show that these GTS schemes are significantly faster to execute than the fixed-grid MOC scheme with space-line interpolation, and in some cases, the accuracy produced by the two GTS schemes cannot be matched by the accuracy of the MOC scheme, even when a Courant number close to one and a large number of grids is used. Furthermore, unlike the MOC solutions, which exhibit increasing numerical dissipation with decreasing Courant numbers, the resolution of the shock fronts was maintained by the GTS schemes even for very low Courant numbers (0.001).

KW - Hydraulic models

KW - Sewers

KW - Transient flow

UR - http://www.scopus.com/inward/record.url?scp=33746169771&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33746169771&partnerID=8YFLogxK

U2 - 10.1061/(ASCE)0733-9429(2006)132:8(800)

DO - 10.1061/(ASCE)0733-9429(2006)132:8(800)

M3 - Article

AN - SCOPUS:33746169771

VL - 132

SP - 800

EP - 813

JO - Journal of Hydraulic Engineering

JF - Journal of Hydraulic Engineering

SN - 0733-9429

IS - 8

ER -