Flow and heat transfer measurements of film injectant from a row of holes with compound angle orientations

Bumsoo Han, Dong Kee Sohn, Joon Sik Lee

Research output: Contribution to journalArticlepeer-review

Abstract

An experiment has been conducted on the flow and heat transfer characteristics of film coolant injected from a row of five holes with compound angle orientations of 35° inclination angle and 45° orientation angle. The Reynolds number number based on the mainstream velocity and injection hole diameter 3.58 × 104. Three-dimensional velocity, film cooling effectiveness and heat transfer coefficient data are presented at three different mass flux ratios of 0.5, 1.0 and 2.0. Flow entrainment has been found between the vortices generated by adjacent injectants. The injectant with compound angle orientation entrains not only the mainstream boundary layer flow but also the adjacent injectant. Because of the flow entrainment, the injectant. With compound angle orientation is characterized by a single vortex while two bound vortices are usually observed in the case of simple angle injection. The strength of the secondary flow depends strongly on the mass flux ratio, which shows significant influence on the film cooling effectiveness and heat transfer coefficient.

Original languageEnglish (US)
Pages (from-to)1137-1146
Number of pages10
JournalKSME International Journal
Volume16
Issue number9
DOIs
StatePublished - Sep 2002
Externally publishedYes

Keywords

  • Compound Angle Orientations
  • Film Cooling
  • Film Cooling Effectiveness
  • Heat Transfer Coefficient
  • Mass Flux Ratio

ASJC Scopus subject areas

  • Mechanical Engineering

Fingerprint

Dive into the research topics of 'Flow and heat transfer measurements of film injectant from a row of holes with compound angle orientations'. Together they form a unique fingerprint.

Cite this