Abstract
Finite element analyses are utilized on a CRAY T94 to calculate hygrothermally induced anisotropic viscoelastic deformations and stresses in plastic IC packages during surface mounting processes, which is an interdisciplinary coupled hygro-thermo-structure interaction problem. The subroutine for element stiffness calculation is dominated by vector operations and achieves about 432 million floating-point operations per second on a CRAY T94. Computational intensity studies (computational intensity is the ratio of flops to memory references) also indicate that it is an efficient algorithm. As a demonstration example, hygrothermally induced stresses in a lead-on-chip (LOC) thin small outline package (TSOP) during the reflow soldering process preceded by a 168 hours 85°C/85% RH moisture soaking test are analyzed.
| Original language | English (US) |
|---|---|
| Pages | 189-201 |
| Number of pages | 13 |
| State | Published - 1997 |
| Externally published | Yes |
| Event | Proceedings of the 1997 5th International Conference on the Application of High-Performance Computers in Engineering, HPC - Santiago de Compostela, Spain Duration: Jul 1 1997 → Jul 1 1997 |
Conference
| Conference | Proceedings of the 1997 5th International Conference on the Application of High-Performance Computers in Engineering, HPC |
|---|---|
| City | Santiago de Compostela, Spain |
| Period | 7/1/97 → 7/1/97 |
ASJC Scopus subject areas
- General Engineering