TY - JOUR
T1 - Experimental Evaluation of a 3-D CZT Imaging Spectrometer for Potential Use in Compton-Enhanced PET Imaging
AU - Jin, Yifei
AU - Streicher, Michael
AU - Yang, Hao
AU - Brown, Steven
AU - He, Zhong
AU - Meng, Ling Jian
N1 - This work was supported in part by NIH/National Institute of Biomedical Imaging and Bioengineering (NIBIB) under Grant R01 EB022388 01 and Grant R01 EB026300 01A1.
PY - 2023/1/1
Y1 - 2023/1/1
N2 - We constructed a prototype positron emission tomography (PET) system and experimentally evaluated large-volume 3-D cadmium zinc telluride (CZT) detectors for potential use in Compton-enhanced PET imaging. The CZT spectrometer offers sub-0.5-mm spatial resolution, an ultrahigh energy resolution (1% @ 511 keV), and the capability of detecting multiple gamma-ray interactions that simultaneously occurred. The system consists of four CZT detector panels with a detection area of around 4.4 cm × 4.4 cm. The distance between the front surfaces of the two opposite CZT detector panels is 80 mm. This system allows us to detect coincident annihilation photons and Compton interactions inside the detectors and then, exploit Compton kinematics to predict the first Compton interaction site and reject chance coincidences. We have developed a numerical integration technique to model the near-field Compton response that incorporates Doppler broadening, detector's finite resolutions, and the distance between the first and second interactions. This method was used to effectively reject random and scattered coincidence events. In the preliminary imaging studies, we have used point sources, line sources, a custom-designed resolution phantom, and a commercial image quality (IQ) phantom to demonstrate an imaging resolution of approximately 0.75 mm in PET images, and Compton-based enhancement.
AB - We constructed a prototype positron emission tomography (PET) system and experimentally evaluated large-volume 3-D cadmium zinc telluride (CZT) detectors for potential use in Compton-enhanced PET imaging. The CZT spectrometer offers sub-0.5-mm spatial resolution, an ultrahigh energy resolution (1% @ 511 keV), and the capability of detecting multiple gamma-ray interactions that simultaneously occurred. The system consists of four CZT detector panels with a detection area of around 4.4 cm × 4.4 cm. The distance between the front surfaces of the two opposite CZT detector panels is 80 mm. This system allows us to detect coincident annihilation photons and Compton interactions inside the detectors and then, exploit Compton kinematics to predict the first Compton interaction site and reject chance coincidences. We have developed a numerical integration technique to model the near-field Compton response that incorporates Doppler broadening, detector's finite resolutions, and the distance between the first and second interactions. This method was used to effectively reject random and scattered coincidence events. In the preliminary imaging studies, we have used point sources, line sources, a custom-designed resolution phantom, and a commercial image quality (IQ) phantom to demonstrate an imaging resolution of approximately 0.75 mm in PET images, and Compton-based enhancement.
KW - Compton scattering
KW - cadmium zinc telluride (CZT) detector
KW - positron emission tomography (PET)
UR - http://www.scopus.com/inward/record.url?scp=85136858546&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85136858546&partnerID=8YFLogxK
U2 - 10.1109/TRPMS.2022.3200010
DO - 10.1109/TRPMS.2022.3200010
M3 - Article
AN - SCOPUS:85136858546
SN - 2469-7311
VL - 7
SP - 18
EP - 32
JO - IEEE Transactions on Radiation and Plasma Medical Sciences
JF - IEEE Transactions on Radiation and Plasma Medical Sciences
IS - 1
ER -