Exergy-based optimal control of a vapor compression system

Neera Jain, Andrew G Alleyne

Research output: Contribution to journalArticle

Abstract

Exergy-based analysis and optimization has been successfully used to design a variety of thermal systems to achieve greater efficiency. However, the advantages afforded by exergy destruction minimization (EDM) at the design stage have not been translated to closed-loop operation of thermal systems such as vapor compression systems (VCSs). Through online optimization and control, VCSs can effectively respond to disturbances, such as weather or varying loads that cannot be accounted for at the design stage, while simultaneously maximizing system efficiency. Furthermore, in applications where VCSs encounter high frequency disturbances, such as in refrigerated transport applications or passenger vehicles, optimizing efficiency at steady-state conditions alone may not lead to significant reductions in energy consumption. In this paper we design the first exergetic, or second law, optimal controller for a canonical four-component vapor compression system (VCS). A lumped parameter moving boundary modeling framework is used to model the two heat exchangers in the VCS. A model predictive controller is then designed and implemented in simulation using a dynamic exergy-based objective function to determine the optimal control actions for the VCS to maximize exergetic efficiency while achieving a desired cooling capacity. Simulation results show that an exergy-based model predictive controller minimizing exergy destruction achieves over 40% greater exergetic efficiency during operation than a comparable first law MPC. Moreover, the distribution of exergy destruction across individual components offers new insight into the effect of variable-speed actuators on system efficiency in VCSs.

Original languageEnglish (US)
Pages (from-to)353-365
Number of pages13
JournalEnergy Conversion and Management
Volume92
DOIs
StatePublished - Mar 1 2015

Fingerprint

Exergy
Vapors
Controllers
Heat exchangers
Actuators
Energy utilization
Cooling

Keywords

  • Control systems
  • Dynamic modeling
  • Exergy destruction minimization
  • Optimal control
  • Vapor compression systems

ASJC Scopus subject areas

  • Renewable Energy, Sustainability and the Environment
  • Nuclear Energy and Engineering
  • Fuel Technology
  • Energy Engineering and Power Technology

Cite this

Exergy-based optimal control of a vapor compression system. / Jain, Neera; Alleyne, Andrew G.

In: Energy Conversion and Management, Vol. 92, 01.03.2015, p. 353-365.

Research output: Contribution to journalArticle

@article{2f3b464f653249f0866a6fcef8387720,
title = "Exergy-based optimal control of a vapor compression system",
abstract = "Exergy-based analysis and optimization has been successfully used to design a variety of thermal systems to achieve greater efficiency. However, the advantages afforded by exergy destruction minimization (EDM) at the design stage have not been translated to closed-loop operation of thermal systems such as vapor compression systems (VCSs). Through online optimization and control, VCSs can effectively respond to disturbances, such as weather or varying loads that cannot be accounted for at the design stage, while simultaneously maximizing system efficiency. Furthermore, in applications where VCSs encounter high frequency disturbances, such as in refrigerated transport applications or passenger vehicles, optimizing efficiency at steady-state conditions alone may not lead to significant reductions in energy consumption. In this paper we design the first exergetic, or second law, optimal controller for a canonical four-component vapor compression system (VCS). A lumped parameter moving boundary modeling framework is used to model the two heat exchangers in the VCS. A model predictive controller is then designed and implemented in simulation using a dynamic exergy-based objective function to determine the optimal control actions for the VCS to maximize exergetic efficiency while achieving a desired cooling capacity. Simulation results show that an exergy-based model predictive controller minimizing exergy destruction achieves over 40{\%} greater exergetic efficiency during operation than a comparable first law MPC. Moreover, the distribution of exergy destruction across individual components offers new insight into the effect of variable-speed actuators on system efficiency in VCSs.",
keywords = "Control systems, Dynamic modeling, Exergy destruction minimization, Optimal control, Vapor compression systems",
author = "Neera Jain and Alleyne, {Andrew G}",
year = "2015",
month = "3",
day = "1",
doi = "10.1016/j.enconman.2014.12.014",
language = "English (US)",
volume = "92",
pages = "353--365",
journal = "Energy Conversion and Management",
issn = "0196-8904",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Exergy-based optimal control of a vapor compression system

AU - Jain, Neera

AU - Alleyne, Andrew G

PY - 2015/3/1

Y1 - 2015/3/1

N2 - Exergy-based analysis and optimization has been successfully used to design a variety of thermal systems to achieve greater efficiency. However, the advantages afforded by exergy destruction minimization (EDM) at the design stage have not been translated to closed-loop operation of thermal systems such as vapor compression systems (VCSs). Through online optimization and control, VCSs can effectively respond to disturbances, such as weather or varying loads that cannot be accounted for at the design stage, while simultaneously maximizing system efficiency. Furthermore, in applications where VCSs encounter high frequency disturbances, such as in refrigerated transport applications or passenger vehicles, optimizing efficiency at steady-state conditions alone may not lead to significant reductions in energy consumption. In this paper we design the first exergetic, or second law, optimal controller for a canonical four-component vapor compression system (VCS). A lumped parameter moving boundary modeling framework is used to model the two heat exchangers in the VCS. A model predictive controller is then designed and implemented in simulation using a dynamic exergy-based objective function to determine the optimal control actions for the VCS to maximize exergetic efficiency while achieving a desired cooling capacity. Simulation results show that an exergy-based model predictive controller minimizing exergy destruction achieves over 40% greater exergetic efficiency during operation than a comparable first law MPC. Moreover, the distribution of exergy destruction across individual components offers new insight into the effect of variable-speed actuators on system efficiency in VCSs.

AB - Exergy-based analysis and optimization has been successfully used to design a variety of thermal systems to achieve greater efficiency. However, the advantages afforded by exergy destruction minimization (EDM) at the design stage have not been translated to closed-loop operation of thermal systems such as vapor compression systems (VCSs). Through online optimization and control, VCSs can effectively respond to disturbances, such as weather or varying loads that cannot be accounted for at the design stage, while simultaneously maximizing system efficiency. Furthermore, in applications where VCSs encounter high frequency disturbances, such as in refrigerated transport applications or passenger vehicles, optimizing efficiency at steady-state conditions alone may not lead to significant reductions in energy consumption. In this paper we design the first exergetic, or second law, optimal controller for a canonical four-component vapor compression system (VCS). A lumped parameter moving boundary modeling framework is used to model the two heat exchangers in the VCS. A model predictive controller is then designed and implemented in simulation using a dynamic exergy-based objective function to determine the optimal control actions for the VCS to maximize exergetic efficiency while achieving a desired cooling capacity. Simulation results show that an exergy-based model predictive controller minimizing exergy destruction achieves over 40% greater exergetic efficiency during operation than a comparable first law MPC. Moreover, the distribution of exergy destruction across individual components offers new insight into the effect of variable-speed actuators on system efficiency in VCSs.

KW - Control systems

KW - Dynamic modeling

KW - Exergy destruction minimization

KW - Optimal control

KW - Vapor compression systems

UR - http://www.scopus.com/inward/record.url?scp=84920940085&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84920940085&partnerID=8YFLogxK

U2 - 10.1016/j.enconman.2014.12.014

DO - 10.1016/j.enconman.2014.12.014

M3 - Article

AN - SCOPUS:84920940085

VL - 92

SP - 353

EP - 365

JO - Energy Conversion and Management

JF - Energy Conversion and Management

SN - 0196-8904

ER -