TY - JOUR
T1 - Evaluation of the sensitivity and specificity of two diagnostic tests for antibodies to pseudorabies virus glycoprotein X.
AU - Weigel, R. M.
AU - Hall, W. F.
AU - Scherba, G.
AU - Siegel, A. M.
AU - Hahn, E. C.
AU - Lehman, J. R.
PY - 1992/7
Y1 - 1992/7
N2 - The diagnostic performance of 2 enzyme-linked immunosorbent assays (gX-T, gX-H) for antibodies to pseudorabies virus (PRV) glycoprotein X (gX) were evaluated using 311 serum samples from a nonvaccinated quarantined herd. When the standardized virus neutralization (VN) test, which uses the Shope strain (VN Shope), was used as the comparative diagnostic standard, the gX-T test had a 7% false-negative rate and a 52% false-positive rate, and the gX-H test had a 19% false-negative rate and a 19% false-positive rate. When the VN test with a Bartha recombinant strain (VN Bartha gIIIKa) was used as the diagnostic standard, the gX-T test had a 9% false-negative rate and a 26% false-positive rate, and the gX-H test had a 24% false-negative rate and a 11% false-positive rate. Thus, the gX-T test was more sensitive and the gX-H test was more specific. Additional diagnostic tests on 79 serum samples from a noninfected herd did not produce false positives for the gX-H test, but there was an 8% false-positive rate for the gX-T test. Previous studies from our laboratory have demonstrated that VN Bartha gIIIKa has higher sensitivity than VN Shope, without losing specificity, and thus is a better comparative diagnostic standard. When adding a suspect range to the gX-T test, using the same criteria as the suspect range for the gX-H test, the false-positive rate of the gX-T test was reduced to 5% when evaluated versus VN Bartha gIIIKa in the infected herd and to 1% for the PRV-negative herd.(ABSTRACT TRUNCATED AT 250 WORDS)
AB - The diagnostic performance of 2 enzyme-linked immunosorbent assays (gX-T, gX-H) for antibodies to pseudorabies virus (PRV) glycoprotein X (gX) were evaluated using 311 serum samples from a nonvaccinated quarantined herd. When the standardized virus neutralization (VN) test, which uses the Shope strain (VN Shope), was used as the comparative diagnostic standard, the gX-T test had a 7% false-negative rate and a 52% false-positive rate, and the gX-H test had a 19% false-negative rate and a 19% false-positive rate. When the VN test with a Bartha recombinant strain (VN Bartha gIIIKa) was used as the diagnostic standard, the gX-T test had a 9% false-negative rate and a 26% false-positive rate, and the gX-H test had a 24% false-negative rate and a 11% false-positive rate. Thus, the gX-T test was more sensitive and the gX-H test was more specific. Additional diagnostic tests on 79 serum samples from a noninfected herd did not produce false positives for the gX-H test, but there was an 8% false-positive rate for the gX-T test. Previous studies from our laboratory have demonstrated that VN Bartha gIIIKa has higher sensitivity than VN Shope, without losing specificity, and thus is a better comparative diagnostic standard. When adding a suspect range to the gX-T test, using the same criteria as the suspect range for the gX-H test, the false-positive rate of the gX-T test was reduced to 5% when evaluated versus VN Bartha gIIIKa in the infected herd and to 1% for the PRV-negative herd.(ABSTRACT TRUNCATED AT 250 WORDS)
UR - http://www.scopus.com/inward/record.url?scp=0026887950&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0026887950&partnerID=8YFLogxK
U2 - 10.1177/104063879200400302
DO - 10.1177/104063879200400302
M3 - Article
C2 - 1325190
AN - SCOPUS:0026887950
SN - 1040-6387
VL - 4
SP - 238
EP - 244
JO - Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc
JF - Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc
IS - 3
ER -