Skip to main navigation Skip to search Skip to main content

Enhancing radiomic feature selection in PET-based heterogeneity analysis through tumor-volume-weighted normalization

  • Goodluck Okoro
  • , Catherine C. Applegate
  • , Michael B. Nelappana
  • , Elaine A. Nielsen
  • , Iwona T. Dobrucki
  • , Lawrence W. Dobrucki

Research output: Contribution to journal › Article › peer-review

Abstract

Purpose Accurate assessment of intratumoral heterogeneity is critical for tumor characterization and monitoring, but variations in tumor size make it difficult to determine whether radiomic differences reflect true biological heterogeneity or mere volume effects. To address this, we developed Tumor-Volume-Weighted Normalization (TVWN), a framework that minimizes size-related biases while preserving intrinsic image heterogeneity. Methods TVWN was evaluated using: (i) computer-simulated tumors (185–800 mm3), (ii) heterogeneous, tumor-mimicking phantoms (10–170 mm3), and (iii) longitudinal PET scans of prostate tumor-bearing mice (35.2–1184 mm3) acquired at four time points. We analyzed 97 radiomic features, including texture metrics from GLRLM and GLSZM, before and after normalization to assess and correct volume dependence. Results TVWN consistently reduced the influence of tumor volume across various acquisition and reconstruction conditions, including different noise levels, Gaussian filtering (2 mm), number of iterations and spatial resolutions (0–6.0 mm FWHM). For example, the volume dependence of Glcm_IDN was effectively reduced (Spearman ρ: 0.290 ± 0.097 to 0.007 ± 0.103 at α = 0.01). In phantom experiments, TVWN reduced the CoV of Glrlm_RE from 17.75 % to 3.18 % in filtered data and from 20.14 % to 3.87 % in unfiltered data. It also enhanced heterogeneity discriminability ( p = 0.0286). In vivo, TVWN decoupled radiomic features from tumor size progression, ensuring that observed changes reflected biological rather than volumetric effects. Conclusion TVWN offers a simple, scalable approach to normalizing radiomic features against tumor volume effects, improving their reproducibility and biological interpretability in longitudinal studies.

Original languageEnglish (US)
Article number105694
JournalPhysica Medica
Volume141
DOIs
StatePublished - Jan 2026

Keywords

  • PET imaging
  • Radiomic features
  • Tumor heterogeneity
  • Tumor-Volume-Weighted Normalization

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging
  • General Physics and Astronomy

Fingerprint

Dive into the research topics of 'Enhancing radiomic feature selection in PET-based heterogeneity analysis through tumor-volume-weighted normalization'. Together they form a unique fingerprint.

Cite this