Energy feedback system for the MIT/Bates linear accelerator

D. H. Barkhuff, S. P. Wells, T. Averett, D. H. Beck, E. J. Beise, D. Cheever, G. Dodson, S. Kowalski, R. D. McKeown, B. A. Mueller, M. Pitt, D. Spayde, C. Tschalaer, A. Zolfaghari

Research output: Contribution to journalArticlepeer-review

Abstract

We report the development and implementation of an energy feedback system for the MIT/Bates Linear Accelerator Center. General requirements of the system are described, as are the specific requirements, features, and components of the system unique to its implementation at the Bates laboratory. We demonstrate that with the system in operation, energy fluctuations correlated with the 60 Hz line voltage and with drifts of thermal origin are reduced by an order of magnitude.

Original languageEnglish (US)
Pages (from-to)187-193
Number of pages7
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume450
Issue number2
DOIs
StatePublished - Aug 11 2000

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

Fingerprint