TY - JOUR
T1 - Effects of pen partition and diffuser type on occupied zone air velocities in typical swine buildings
AU - Priest, John B.
AU - Maghirang, Ronaldo G.
AU - Riskowski, Gerald L.
AU - Christianson, Leslie L.
AU - Berglind, Eric J.
PY - 1999
Y1 - 1999
N2 - Research is needed to determine the effects of the type of pen partition, type of diffuser, and ventilation rate on room air and air contaminant distribution in animal buildings. Twelve tests were conducted to investigate the influence of supply air diffuser type (linear slot, sidewall, ceiling), partition type (open vs. solid), and ventilation rate (high vs. low) on air velocity in the animal occupied zone (≤2 ft above the floor) in a full-scale model of typical swine nursery buildings. Results indicated that ventilation rate had little influence on the velocity in the animal occupied zone. The type of partition influenced the mean velocity for the linear slot diffuser; it had little influence on mean velocity for the sidewall and ceiling diffusers. Additionally, the mean velocity varied with the type of diffuser; overall mean velocity at the animal occupied zone for the ceiling diffuser was 25% to 34% higher than that for the sidewall and linear slot diffusers.
AB - Research is needed to determine the effects of the type of pen partition, type of diffuser, and ventilation rate on room air and air contaminant distribution in animal buildings. Twelve tests were conducted to investigate the influence of supply air diffuser type (linear slot, sidewall, ceiling), partition type (open vs. solid), and ventilation rate (high vs. low) on air velocity in the animal occupied zone (≤2 ft above the floor) in a full-scale model of typical swine nursery buildings. Results indicated that ventilation rate had little influence on the velocity in the animal occupied zone. The type of partition influenced the mean velocity for the linear slot diffuser; it had little influence on mean velocity for the sidewall and ceiling diffusers. Additionally, the mean velocity varied with the type of diffuser; overall mean velocity at the animal occupied zone for the ceiling diffuser was 25% to 34% higher than that for the sidewall and linear slot diffusers.
UR - http://www.scopus.com/inward/record.url?scp=0033326092&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0033326092&partnerID=8YFLogxK
M3 - Conference article
AN - SCOPUS:0033326092
SN - 0001-2505
VL - 105
SP - PART 2/-
JO - ASHRAE Transactions
JF - ASHRAE Transactions
T2 - ASHRAE Annual Meeting
Y2 - 18 June 1999 through 23 June 1999
ER -