TY - JOUR
T1 - Effect of venting the periodic reverse vapor flow on the performance of a microchannel evaporator in air-conditioning systems
AU - Tuo, Hanfei
AU - Hrnjak, Pega
N1 - Funding Information:
We are grateful for financial and technical support from the Air Conditioning and Refrigeration Center (ACRC) at the University of Illinois and CTS.
Copyright:
Copyright 2013 Elsevier B.V., All rights reserved.
PY - 2014
Y1 - 2014
N2 - This paper proposes a novel solution to reduce the impacts of periodic reverse flow and induced boiling fluctuations on the performance of a microchannel evaporator used in an air-conditioning or other similar refrigeration system. Reverse vapor trapped within the inlet header is continuously vented bypassing microchannels. Simultaneous flow visualizations and measurements quantified the effects of venting the reverse vapor on the evaporator performance. The vapor-liquid interface in the inlet header is elevated above all the microchannel inlets, resulting in more uniform liquid distribution among channels. Evaporator surface temperatures measured by an infrared camera oscillate with reduced amplitude (less than 1 C) compared to the situation without venting, indicating more stable boiling heat transfer and two-phase flow within the microchannels. The evaporator pressure drop is reduced up to about 15% due to removal of the reversed vapor flow. In addition, the reverse vapor flow is characterized for the first time through this method. Both its average flow rate and oscillation amplitude increase with average heat flux, while the oscillation period is reduced. Compared to the total refrigerant flow rate supplied to the evaporator, the average reverse vapor flow is in the range of 2-8% at the conditions explored.
AB - This paper proposes a novel solution to reduce the impacts of periodic reverse flow and induced boiling fluctuations on the performance of a microchannel evaporator used in an air-conditioning or other similar refrigeration system. Reverse vapor trapped within the inlet header is continuously vented bypassing microchannels. Simultaneous flow visualizations and measurements quantified the effects of venting the reverse vapor on the evaporator performance. The vapor-liquid interface in the inlet header is elevated above all the microchannel inlets, resulting in more uniform liquid distribution among channels. Evaporator surface temperatures measured by an infrared camera oscillate with reduced amplitude (less than 1 C) compared to the situation without venting, indicating more stable boiling heat transfer and two-phase flow within the microchannels. The evaporator pressure drop is reduced up to about 15% due to removal of the reversed vapor flow. In addition, the reverse vapor flow is characterized for the first time through this method. Both its average flow rate and oscillation amplitude increase with average heat flux, while the oscillation period is reduced. Compared to the total refrigerant flow rate supplied to the evaporator, the average reverse vapor flow is in the range of 2-8% at the conditions explored.
KW - Boiling fluctuation
KW - Microchannel evaporator
KW - Periodic reverse flow
UR - http://www.scopus.com/inward/record.url?scp=84887029944&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84887029944&partnerID=8YFLogxK
U2 - 10.1016/j.ijheatmasstransfer.2013.08.095
DO - 10.1016/j.ijheatmasstransfer.2013.08.095
M3 - Article
AN - SCOPUS:84887029944
SN - 0017-9310
VL - 69
SP - 66
EP - 76
JO - International Journal of Heat and Mass Transfer
JF - International Journal of Heat and Mass Transfer
ER -