Effect of lubricant on two-phase refrigerant distribution in microchannel evaporator

Research output: Contribution to journalConference articlepeer-review

Abstract

This paper presents a model analysis of oil effects on the distribution of two phase refrigerant in a parallel flow microchannel evaporator. A microchannel evaporator model developed and presented earlier (SAE paper 2012-01-0321) is enhanced by inclusion of the thermodynamic and transport properties of refrigerant-oil mixture and their impact on boiling heat transfer and pressure drop characteristics. R134a and PAG oil are selected as the working pair. Viscosity effect and OCR effect on refrigerant distribution are investigated using this model, and the results show that 1) High viscosity is detrimental for refrigerant distribution. 2) As OCR increases, distribution becomes worse; but at very high OCR, distribution becomes better. Some initial experimental results show that distribution becomes worse when OCR changes from 0.1% to 3%.

Original languageEnglish (US)
JournalSAE Technical Papers
Volume2
StatePublished - Jan 1 2013
EventSAE 2013 World Congress and Exhibition - Detroit, MI, United States
Duration: Apr 16 2013Apr 18 2013

ASJC Scopus subject areas

  • Automotive Engineering
  • Safety, Risk, Reliability and Quality
  • Pollution
  • Industrial and Manufacturing Engineering

Fingerprint Dive into the research topics of 'Effect of lubricant on two-phase refrigerant distribution in microchannel evaporator'. Together they form a unique fingerprint.

Cite this