TY - JOUR
T1 - Droplet Microfluidics with MALDI-MS Detection
T2 - The Effects of Oil Phases in GABA Analysis
AU - Bell, Sara E.
AU - Park, Insu
AU - Rubakhin, Stanislav S.
AU - Bashir, Rashid
AU - Vlasov, Yurii
AU - Sweedler, Jonathan V.
N1 - Publisher Copyright:
© 2021 The Authors. Published by American Chemical Society.
PY - 2021/12/15
Y1 - 2021/12/15
N2 - Microfluidic and mass spectrometry (MS) methods are widely used to sample and probe the chemical composition of biological systems to elucidate chemical correlates of their healthy and disease states. Though matrix-assisted laser desorption/ionization-mass spectrometry (MALDI)-MS has been hyphenated to droplet microfluidics for offline analyses, the effects of parameters related to droplet generation, such as the type of oil phase used, have been understudied. To characterize these effects, five different oil phases were tested in droplet microfluidics for producing samples for MALDI-MS analysis. Picoliter to nanoliter aqueous droplets containing 0.1 to 100 mM γ-aminobutyric acid (GABA) and inorganic salts were generated inside a polydimethylsiloxane microfluidic chip and deposited onto a conductive glass slide. Optical microscopy, Raman spectroscopy, and MALDI-mass spectrometry imaging (MSI) of the droplet samples and surrounding areas revealed patterns of solvent and oil evaporation and analyte deposition. Optical microscopy detected the presence of salt crystals in 50-100 μm diameter dried droplets, and Raman and MSI were used to correlate GABA signals to the visible droplet footprints. MALDI-MS analyses revealed that droplets prepared in the presence of octanol oil led to the poorest detectability of GABA, whereas the oil phases containing FC-40 provided the best detectability; GABA signal was localized to the footprint of 65 pL droplets with a limit of detection of 23 amol. The effect of the surfactant perfluorooctanol on analyte detection was also investigated.
AB - Microfluidic and mass spectrometry (MS) methods are widely used to sample and probe the chemical composition of biological systems to elucidate chemical correlates of their healthy and disease states. Though matrix-assisted laser desorption/ionization-mass spectrometry (MALDI)-MS has been hyphenated to droplet microfluidics for offline analyses, the effects of parameters related to droplet generation, such as the type of oil phase used, have been understudied. To characterize these effects, five different oil phases were tested in droplet microfluidics for producing samples for MALDI-MS analysis. Picoliter to nanoliter aqueous droplets containing 0.1 to 100 mM γ-aminobutyric acid (GABA) and inorganic salts were generated inside a polydimethylsiloxane microfluidic chip and deposited onto a conductive glass slide. Optical microscopy, Raman spectroscopy, and MALDI-mass spectrometry imaging (MSI) of the droplet samples and surrounding areas revealed patterns of solvent and oil evaporation and analyte deposition. Optical microscopy detected the presence of salt crystals in 50-100 μm diameter dried droplets, and Raman and MSI were used to correlate GABA signals to the visible droplet footprints. MALDI-MS analyses revealed that droplets prepared in the presence of octanol oil led to the poorest detectability of GABA, whereas the oil phases containing FC-40 provided the best detectability; GABA signal was localized to the footprint of 65 pL droplets with a limit of detection of 23 amol. The effect of the surfactant perfluorooctanol on analyte detection was also investigated.
KW - GABA
KW - MALDI
KW - droplet microfluidics
KW - mass spectrometry
KW - neurotransmitter
KW - perfluorinated oil
KW - picoliter
UR - http://www.scopus.com/inward/record.url?scp=85133504324&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85133504324&partnerID=8YFLogxK
U2 - 10.1021/acsmeasuresciau.1c00017
DO - 10.1021/acsmeasuresciau.1c00017
M3 - Article
AN - SCOPUS:85133504324
SN - 2694-250X
VL - 1
SP - 147
EP - 156
JO - ACS Measurement Science Au
JF - ACS Measurement Science Au
IS - 3
ER -