Comparison of thermal dilution and electrical impedance dilution methods for measurement of cardiac output in standing and exercising horses

Pamela A. Wilkins, Raymond C. Boston, Robin D. Gleed, Alan Dobson

Research output: Contribution to journalArticlepeer-review

Abstract

Objective - To compare cardiac output measured in the pulmonary artery and a carotid artery by use of thermal and electrical impedance dilution. Animals - 7 fit, clinically normal Standardbreds between 2 and 5 years of age. Procedure - Transient changes in electrical impedance and temperature of blood were induced by bolus injections of ice-cold saline hypertonic (6% and 9% NaCl) solutions. Cardiac output was calculated by applying Stewart-Hamilton principles to the indicator dilution transients. Measurements were made during sequential exercise episodes on a level treadmill over approximately an 8-fold range of cardiac output values. Results - We detected agreement between cardiac output determined by use of electrical impedance dilution at the pulmonary artery and carotid artery. Cardiac output from thermal dilution measured at the carotid artery exceeded that measured at the pulmonary artery. Cardiac output from the thermal dilution technique exceeded cardiac output from the electrical impedance dilution technique at both locations. Conclusions and clinical relevance - The electrical impedance indicator is conserved on first transit; therefore cardiac output measured by electrical impedance dilution at the carotid artery is reliable over a large range of values. Thermal dilution provides a larger estimate of cardiac output, compared with the electrical impedance dilution technique, probably because of a loss of indicator. The transpulmonary electrical impedance dilution technique may have potential for clinical application, particularly in animals in which catheterization of the pulmonary artery is not appropriate or blood loss must be minimized.

Original languageEnglish (US)
Pages (from-to)878-884
Number of pages7
JournalAmerican journal of veterinary research
Volume66
Issue number5
DOIs
StatePublished - May 2005
Externally publishedYes

ASJC Scopus subject areas

  • General Veterinary

Fingerprint

Dive into the research topics of 'Comparison of thermal dilution and electrical impedance dilution methods for measurement of cardiac output in standing and exercising horses'. Together they form a unique fingerprint.

Cite this