Abstract
We have experimentally characterized the light-output response of a deuterated trans-stilbene (stilbene-d12) crystal to quasi-monoenergetic neutrons in the 0.8 to 4.4 MeV energy range. These data allowed us to perform neutron spectroscopy measurements of a DT 14.1 MeV source and a 239PuBe source by unfolding the impinging neutron spectrum from the measured light-output response. The stilbene-d12 outperforms a 1H−stilbene of similar size when comparing the shape of the unfolded spectra and the reference ones. These results confirm the viability of non-hygroscopic stilbene-d12 crystal for direct neutron spectroscopy without need for time-of-flight measurements. This capability makes stilbene-d12 a well suited detector for fast-neutron spectroscopy in many applications including nuclear reaction studies, radiation protection, nuclear non-proliferation, and space travel.
Original language | English (US) |
---|---|
Article number | 165822 |
Journal | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
Volume | 1018 |
DOIs | |
State | Published - Dec 1 2021 |
Keywords
- Deuterated scintillators
- Neutron spectroscopy
- Scintillation detector
- Spectral unfolding
ASJC Scopus subject areas
- Nuclear and High Energy Physics
- Instrumentation