Capillary extraction of the ionic liquid [Bmim][DCA] for variable flow rate operations

Shawn W. Miller, Benjamin D. Prince, Joshua L. Rovey

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The ionic liquid [Bmim][DCA] is a propellant candidate in a standalone electrospray thruster or in a dual-mode propulsion system consisting of a chemical system and an electrospray system. Since limited published data exists for [Bmim][DCA], the electrospray characteristics are relatively unknown. Emission testing of the ionic liquid has been conducted to characterize the [Bmim][DCA] electrospray plume for both an external flow titanium needle and internal flow capillary. Mass spectrometric, retarding potential, and angle distribution measurements were collected for the positive polarity ions emitted from [Bmim][DCA] wetted emitters with nominal extraction voltages between 1 kV to 2.5 kV. The titanium needle operated at a sizably reduced liquid flow rate in comparison to the capillary. As such, only the major species of Bmim+([Bmim][DCA])n with n=0,1 were identifiable in the quadrupole measurement range of 0-1000 amu and were formed at or near the needle potential. A typical needle angle distribution was found in these measurements. For the capillary emitter, flow rates from 0.27 nL/s to 2.18 nL/s were used to investigate corresponding alterations in the electrospray beam. The aim of the investigation was to ascertain the ability to "tune" or "dial-in" an electrospray thruster to specific ion or droplet sizes and thus specific performance levels. Unlike the limited species observed from the needle emission, the capillary measurements indicated the presence of n=0,1,2,3,4 cation species with large mass droplet contributions. The lowest flow rates indicated the highest levels of ions in the measurement range of 0-1000 amu with a mix of large mass droplets. For increasing flow rate, species < 500 amu ceased to exist leaving only the n=2,3,4 species mixed with large mass droplets in the electrospray beam. All ion species exceeded the quadrupole mass range at the upper flow rates. Ions emitted from the capillary were formed at levels below the emitter potential. Ohmic losses in the ionic liquid are likely the cause for the less energetic ions. Angular distribution measurements indicated broadening of the beam current and mass distribution for increasing flow rates.

Original languageEnglish (US)
Title of host publication48th AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit 2012
PublisherAmerican Institute of Aeronautics and Astronautics Inc.
ISBN (Print)9781600869358
DOIs
StatePublished - 2012
Externally publishedYes
Event48th AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit 2012 - Atlanta, GA, United States
Duration: Jul 30 2012Aug 1 2012

Publication series

Name48th AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit 2012

Conference

Conference48th AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit 2012
Country/TerritoryUnited States
CityAtlanta, GA
Period7/30/128/1/12

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Aerospace Engineering
  • Control and Systems Engineering
  • Electrical and Electronic Engineering
  • Mechanical Engineering

Fingerprint

Dive into the research topics of 'Capillary extraction of the ionic liquid [Bmim][DCA] for variable flow rate operations'. Together they form a unique fingerprint.

Cite this