TY - JOUR
T1 - Automated microflow NMR
T2 - Routine analysis of five-microliter samples
AU - Jansma, Ariane
AU - Chuan, Tiffany
AU - Albrecht, Robert W.
AU - Olson, Dean L.
AU - Peck, Timothy L.
AU - Geierstanger, Bernhard H.
PY - 2005/10/1
Y1 - 2005/10/1
N2 - A microflow CapNMR probe double-tuned for 1H and 13C was installed on a 400-MHz NMR spectrometer and interfaced to an automated liquid handler. Individual samples dissolved in DMSO-d6 are submitted for NMR analysis in vials containing as little as 10 μL of sample. Sets of samples are submitted in a low-volume 384-well plate. Of the 10 μL of sample per well, as with vials, 5 μL is injected into the microflow NMR probe for analysis. For quality control of chemical libraries, 1D NMR spectra are acquired under full automation from 384-well plates on as many as 130 compounds within 24 h using 128 scans per spectrum and a sample-to-sample cycle time of ∼11 min. Because of the low volume requirements and high mass sensitivity of the microflow NMR system, 30 nmol of a typical small molecule is sufficient to obtain high-quality, well-resolved, ID proton or 2D COSY NMR spectra in ∼6 or 20 min of data acquisition time per experiment, respectively. Implementation of pulse programs with automated solvent peak identification and suppression allow for reliable data collection, even for samples submitted in fully protonated DMSO. The automated microflow NMR system is controlled and monitored using web-based software.
AB - A microflow CapNMR probe double-tuned for 1H and 13C was installed on a 400-MHz NMR spectrometer and interfaced to an automated liquid handler. Individual samples dissolved in DMSO-d6 are submitted for NMR analysis in vials containing as little as 10 μL of sample. Sets of samples are submitted in a low-volume 384-well plate. Of the 10 μL of sample per well, as with vials, 5 μL is injected into the microflow NMR probe for analysis. For quality control of chemical libraries, 1D NMR spectra are acquired under full automation from 384-well plates on as many as 130 compounds within 24 h using 128 scans per spectrum and a sample-to-sample cycle time of ∼11 min. Because of the low volume requirements and high mass sensitivity of the microflow NMR system, 30 nmol of a typical small molecule is sufficient to obtain high-quality, well-resolved, ID proton or 2D COSY NMR spectra in ∼6 or 20 min of data acquisition time per experiment, respectively. Implementation of pulse programs with automated solvent peak identification and suppression allow for reliable data collection, even for samples submitted in fully protonated DMSO. The automated microflow NMR system is controlled and monitored using web-based software.
UR - http://www.scopus.com/inward/record.url?scp=26444484278&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=26444484278&partnerID=8YFLogxK
U2 - 10.1021/ac050936w
DO - 10.1021/ac050936w
M3 - Article
C2 - 16194121
AN - SCOPUS:26444484278
SN - 0003-2700
VL - 77
SP - 6509
EP - 6515
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 19
ER -