Assessment of low-contrast detectability for compressed digital chest images

Larry T. Cook, Michael F. Insana, Michael A. McFadden, Timothy J. Hall, Glendon G. Cox

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The ability of human observers to detect low-contrast targets in screen-film (SF) images, computed radiographic (CR) images, and compressed CR images was measured using contrast detail (CD) analysis. The results of these studies were used to design a two-alternative forced-choice (2AFC) experiment to investigate the detectability of nodules in adult chest radiographs. CD curves for a common screen-film system were compared with CR images compressed up to 125:1. Data from clinical chest exams were used to define a CD region of clinical interest that sufficiently challenged the observer. From these data, simulated lesions were introduced into 100 normal CR chest films, and forced-choice observer performance studies were performed. CR images were compressed using a full-frame discrete cosine transform technique, where the 2D Fourier space was divided into four areas of different quantization depending on the cumulative power spectrum (energy) of each image. The characteristic curve of the CR images was adjusted so that optical densities matched those of the SF system. The CD curves for SF and uncompressed CR systems were statistically equivalent. The slope of the CD curve for each was - 1.0, as predicted by the Rose model. There was a significant degradation in detection found for CR images compressed to 125:1. Furthermore, contrast-detail analysis demonstrated that many pulmonary nodules encountered in clinical practice are significantly above the average observer threshold for detection. We designed a 2AFC observer study using simulated 1-cm lesions introduced into normal CR chest radiographs. Detectability was reduced for all compressed CR radiographs.

Original languageEnglish (US)
Title of host publicationProceedings of SPIE - The International Society for Optical Engineering
EditorsHarold L. Kundel
PublisherPubl by Society of Photo-Optical Instrumentation Engineers
Pages159-169
Number of pages11
ISBN (Print)0819414611
StatePublished - 1994
Externally publishedYes
EventMedical Imaging 1994: Image Perception - Newport Beach, CA, USA
Duration: Feb 17 1994Feb 18 1994

Publication series

NameProceedings of SPIE - The International Society for Optical Engineering
Volume2166
ISSN (Print)0277-786X

Other

OtherMedical Imaging 1994: Image Perception
CityNewport Beach, CA, USA
Period2/17/942/18/94

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Computer Science Applications
  • Applied Mathematics
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Assessment of low-contrast detectability for compressed digital chest images'. Together they form a unique fingerprint.

Cite this