Analysis of active-clamp response to power-on ESD: Power supply integrity and performance tradeoffs

Robert Mertens, Nicholas Thomson, Yang Xiu, Elyse Rosenbaum

Research output: Contribution to journalArticle

Abstract

An active rail clamp circuit provides protection against component-level ESD; this work explores the challenges associated with designing a rail clamp to additionally provide protection when the IC is powered on. The fast transient response required to protect against ESD makes it difficult to design a stable circuit and introduces tradeoffs between supply integrity and the clamping characteristic. This work presents an analysis of how these performance metrics are affected by device sizes. Interactions between a rail clamp circuit, which may be an active or passive clamp, and the parasitic elements of the package and board are examined; it is shown that these interactions may briefly power down the supply.

Original languageEnglish (US)
Article number7177068
Pages (from-to)263-271
Number of pages9
JournalIEEE Transactions on Device and Materials Reliability
Volume15
Issue number3
DOIs
StatePublished - Sep 1 2015

Fingerprint

Clamping devices
Rails
Networks (circuits)
Transient analysis

Keywords

  • Circuit stability
  • Electromagnetic compatibility
  • Electrostatic discharge
  • Immunity testing
  • Integrated circuit reliability
  • System-level ESD

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Safety, Risk, Reliability and Quality
  • Electrical and Electronic Engineering

Cite this

Analysis of active-clamp response to power-on ESD : Power supply integrity and performance tradeoffs. / Mertens, Robert; Thomson, Nicholas; Xiu, Yang; Rosenbaum, Elyse.

In: IEEE Transactions on Device and Materials Reliability, Vol. 15, No. 3, 7177068, 01.09.2015, p. 263-271.

Research output: Contribution to journalArticle

@article{3a2f9f0f5f5d4b39b3c5721617b0ae24,
title = "Analysis of active-clamp response to power-on ESD: Power supply integrity and performance tradeoffs",
abstract = "An active rail clamp circuit provides protection against component-level ESD; this work explores the challenges associated with designing a rail clamp to additionally provide protection when the IC is powered on. The fast transient response required to protect against ESD makes it difficult to design a stable circuit and introduces tradeoffs between supply integrity and the clamping characteristic. This work presents an analysis of how these performance metrics are affected by device sizes. Interactions between a rail clamp circuit, which may be an active or passive clamp, and the parasitic elements of the package and board are examined; it is shown that these interactions may briefly power down the supply.",
keywords = "Circuit stability, Electromagnetic compatibility, Electrostatic discharge, Immunity testing, Integrated circuit reliability, System-level ESD",
author = "Robert Mertens and Nicholas Thomson and Yang Xiu and Elyse Rosenbaum",
year = "2015",
month = "9",
day = "1",
doi = "10.1109/TDMR.2015.2464222",
language = "English (US)",
volume = "15",
pages = "263--271",
journal = "IEEE Transactions on Device and Materials Reliability",
issn = "1530-4388",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "3",

}

TY - JOUR

T1 - Analysis of active-clamp response to power-on ESD

T2 - Power supply integrity and performance tradeoffs

AU - Mertens, Robert

AU - Thomson, Nicholas

AU - Xiu, Yang

AU - Rosenbaum, Elyse

PY - 2015/9/1

Y1 - 2015/9/1

N2 - An active rail clamp circuit provides protection against component-level ESD; this work explores the challenges associated with designing a rail clamp to additionally provide protection when the IC is powered on. The fast transient response required to protect against ESD makes it difficult to design a stable circuit and introduces tradeoffs between supply integrity and the clamping characteristic. This work presents an analysis of how these performance metrics are affected by device sizes. Interactions between a rail clamp circuit, which may be an active or passive clamp, and the parasitic elements of the package and board are examined; it is shown that these interactions may briefly power down the supply.

AB - An active rail clamp circuit provides protection against component-level ESD; this work explores the challenges associated with designing a rail clamp to additionally provide protection when the IC is powered on. The fast transient response required to protect against ESD makes it difficult to design a stable circuit and introduces tradeoffs between supply integrity and the clamping characteristic. This work presents an analysis of how these performance metrics are affected by device sizes. Interactions between a rail clamp circuit, which may be an active or passive clamp, and the parasitic elements of the package and board are examined; it is shown that these interactions may briefly power down the supply.

KW - Circuit stability

KW - Electromagnetic compatibility

KW - Electrostatic discharge

KW - Immunity testing

KW - Integrated circuit reliability

KW - System-level ESD

UR - http://www.scopus.com/inward/record.url?scp=84940977387&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84940977387&partnerID=8YFLogxK

U2 - 10.1109/TDMR.2015.2464222

DO - 10.1109/TDMR.2015.2464222

M3 - Article

AN - SCOPUS:84940977387

VL - 15

SP - 263

EP - 271

JO - IEEE Transactions on Device and Materials Reliability

JF - IEEE Transactions on Device and Materials Reliability

SN - 1530-4388

IS - 3

M1 - 7177068

ER -