TY - JOUR
T1 - Accuracy and reproducibility of absolute quantification of myocardial focal tracer uptake from molecularly targeted SPECT/CT
T2 - A canine validation
AU - Liu, Yi Hwa
AU - Sahul, Zakir
AU - Weyman, Christopher A.
AU - Dione, Donald P.
AU - Dobrucki, Wawrzyniec L.
AU - Mekkaoui, Choukri
AU - Brennan, Matthew P.
AU - Ryder, William J.
AU - Sinusas, Albert J.
PY - 2011/3/1
Y1 - 2011/3/1
N2 - Accurate and reproducible SPECT quantification of myocardial molecular processes remains a challenge because of the complication of heterogeneous background and extracardiac activity adjacent to the heart, which causes errors in the estimation of myocardial focal tracer uptake. Our aim in this study was to introduce a heuristic method for the correction of extracardiac activity into SPECT quantification and validate the modified quantification method for accuracy and reproducibility using a canine model. Methods: Dual-isotope- targeted 99mTc and 201Tl perfusion SPECT images were acquired using a hybrid SPECT/CT camera in 6 dogs at 2 wk after myocardial infarction. Images were reconstructed with and without CT-based attenuation correction, and the reconstructed SPECT images were filtered and quantified simultaneously with incorporation of extracardiac radioactivity correction, gaussian fitting, and total-count sampling. Absolute myocardial focal tracer uptake was quantified from SPECT images using 3 different normal limits (maximum entropy [ME], mean-squared-error minimization [MSEM], and global minimum [GM]). SPECT-quantified percentage injected dose (%ID) was calculated and compared with the well-counted radioactivity measured from the postmortem myocardial tissue. SPECT quantitative processing was performed by 2 different individuals with extensive experience in cardiac image processing, to assess reproducibility of the quantitative analysis. Results: Correlations between SPECT-quantified and well-counted %IDs using 3 different normal limits were excellent (ME: r = 0.82, y = 0.932x - 0.0102; MSEM: r = 0.73, y = 1.1413x - 0.0052; and GM: r = 0.7, y = 1.2147x - 0.0002). SPECT quantification using ME normal limits resulted in an underestimation of %ID, as compared with well-counted %ID. Myocardial focal tracer uptake quantified from SPECT images without CT-based attenuation correction was significantly lower than that with the attenuation correction. The %IDs quantified from attenuation-corrected SPECT images using MSEM and GM normal limits were not significantly different from wellcounted %IDs. Reproducibility of the SPECT quantitative analysis was excellent (ME: r = 0.98, y = 0.9221x + 0.0001; MSEM: r = 0.97, y = 0.9357x + 0.0004; and GM: r = 0.96, y = 0.9026x + 0.001). Conclusion: Our SPECT/CT quantification algorithm for the assessment of regional radioactivity may allow for accurate and reproducible serial noninvasive evaluation of molecularly targeted tracers in the myocardium.
AB - Accurate and reproducible SPECT quantification of myocardial molecular processes remains a challenge because of the complication of heterogeneous background and extracardiac activity adjacent to the heart, which causes errors in the estimation of myocardial focal tracer uptake. Our aim in this study was to introduce a heuristic method for the correction of extracardiac activity into SPECT quantification and validate the modified quantification method for accuracy and reproducibility using a canine model. Methods: Dual-isotope- targeted 99mTc and 201Tl perfusion SPECT images were acquired using a hybrid SPECT/CT camera in 6 dogs at 2 wk after myocardial infarction. Images were reconstructed with and without CT-based attenuation correction, and the reconstructed SPECT images were filtered and quantified simultaneously with incorporation of extracardiac radioactivity correction, gaussian fitting, and total-count sampling. Absolute myocardial focal tracer uptake was quantified from SPECT images using 3 different normal limits (maximum entropy [ME], mean-squared-error minimization [MSEM], and global minimum [GM]). SPECT-quantified percentage injected dose (%ID) was calculated and compared with the well-counted radioactivity measured from the postmortem myocardial tissue. SPECT quantitative processing was performed by 2 different individuals with extensive experience in cardiac image processing, to assess reproducibility of the quantitative analysis. Results: Correlations between SPECT-quantified and well-counted %IDs using 3 different normal limits were excellent (ME: r = 0.82, y = 0.932x - 0.0102; MSEM: r = 0.73, y = 1.1413x - 0.0052; and GM: r = 0.7, y = 1.2147x - 0.0002). SPECT quantification using ME normal limits resulted in an underestimation of %ID, as compared with well-counted %ID. Myocardial focal tracer uptake quantified from SPECT images without CT-based attenuation correction was significantly lower than that with the attenuation correction. The %IDs quantified from attenuation-corrected SPECT images using MSEM and GM normal limits were not significantly different from wellcounted %IDs. Reproducibility of the SPECT quantitative analysis was excellent (ME: r = 0.98, y = 0.9221x + 0.0001; MSEM: r = 0.97, y = 0.9357x + 0.0004; and GM: r = 0.96, y = 0.9026x + 0.001). Conclusion: Our SPECT/CT quantification algorithm for the assessment of regional radioactivity may allow for accurate and reproducible serial noninvasive evaluation of molecularly targeted tracers in the myocardium.
KW - Dual-isotope imaging
KW - Hot spot quantification
KW - Molecularly targeted cardiac imaging
KW - SPECT/CT
UR - http://www.scopus.com/inward/record.url?scp=79952777554&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79952777554&partnerID=8YFLogxK
U2 - 10.2967/jnumed.110.082214
DO - 10.2967/jnumed.110.082214
M3 - Article
C2 - 21321271
AN - SCOPUS:79952777554
SN - 0161-5505
VL - 52
SP - 453
EP - 460
JO - Journal of Nuclear Medicine
JF - Journal of Nuclear Medicine
IS - 3
ER -