TY - JOUR
T1 - A stilbene-based fluoroionophore for copper ion sensing in both reduced and oxidized environments
AU - Zhu, Ming Qiang
AU - Gu, Zheng
AU - Zhang, Rong
AU - Xiang, Jian Nan
AU - Nie, Shuming
N1 - Funding Information:
This work was financially supported by the NSFC ( 20874025 ), the Program for New Century Excellent Talents in Universities (NCET-07-00273), the “973” National Key Basic Research Program of China ( 2007CB310500 ), The Project Sponsored by the Scientific Research Foundation for the Returned Overseas Chinese Scholars , State Education Ministry, the Doctoral Fund of Ministry of Education of China ( 20060532022 ), the 985 fund of HNU.
PY - 2010/4/15
Y1 - 2010/4/15
N2 - The high sensitivity and abundance of fluorophores makes fluorescence technique among one of the most promising tools to develop chemo- and biosensors. Fluorescent sensors for ions, also called fluoroionophores, are commonly composed of an ion recognition unit (ionophore) and a fluorogenic unit (fluorophore). Here we report the synthesis and characterization of a new stilbene derivative conjugated with the di-2-picolylamine (dpa) group. It is found that the fluorescence of the stilbene derivative using dpa as ionophore is sensitive to copper ions, including Cu2+ (oxidized state) and Cu+ (reduced state). The sensitive and selective stilbene-based fluoroionophore for copper ions are based on the internal charge transfer along with the electron donor-π-acceptor stilbene motif and incorporate a dpa-containing aniline-derivatized ligand framework. By modifying the stilbene with di-2-picolylamine (dpa), the significant fluorescence quenching was observed upon binding with copper ions involving both the reduced and oxidized environments, indicating the great sensitivity and specificity for copper ion sensing. The presence of metal ions such as Ag+, Al3+, Ba2+, Ca2+, Cd2+, Co2+, Cr3+, Fe2+, Fe3+, Hg2+, K+, Mg2+, Mn2+, Na+, Ni2+, Pb2+, Sn2+, and Zn2+ had little influence on the selectivity and sensitivity of Cu2+ and Cu+. The optical sensor design undertakes promising for potential application to multiplex sensing of different analytes through distinct ligand conjugation and functionalization of individual fluorophore.
AB - The high sensitivity and abundance of fluorophores makes fluorescence technique among one of the most promising tools to develop chemo- and biosensors. Fluorescent sensors for ions, also called fluoroionophores, are commonly composed of an ion recognition unit (ionophore) and a fluorogenic unit (fluorophore). Here we report the synthesis and characterization of a new stilbene derivative conjugated with the di-2-picolylamine (dpa) group. It is found that the fluorescence of the stilbene derivative using dpa as ionophore is sensitive to copper ions, including Cu2+ (oxidized state) and Cu+ (reduced state). The sensitive and selective stilbene-based fluoroionophore for copper ions are based on the internal charge transfer along with the electron donor-π-acceptor stilbene motif and incorporate a dpa-containing aniline-derivatized ligand framework. By modifying the stilbene with di-2-picolylamine (dpa), the significant fluorescence quenching was observed upon binding with copper ions involving both the reduced and oxidized environments, indicating the great sensitivity and specificity for copper ion sensing. The presence of metal ions such as Ag+, Al3+, Ba2+, Ca2+, Cd2+, Co2+, Cr3+, Fe2+, Fe3+, Hg2+, K+, Mg2+, Mn2+, Na+, Ni2+, Pb2+, Sn2+, and Zn2+ had little influence on the selectivity and sensitivity of Cu2+ and Cu+. The optical sensor design undertakes promising for potential application to multiplex sensing of different analytes through distinct ligand conjugation and functionalization of individual fluorophore.
KW - Copper ions
KW - Fluoroionophores
KW - Internal charge transfer
KW - Sensor
KW - Stilbene
UR - http://www.scopus.com/inward/record.url?scp=77249143948&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77249143948&partnerID=8YFLogxK
U2 - 10.1016/j.talanta.2010.01.002
DO - 10.1016/j.talanta.2010.01.002
M3 - Article
C2 - 20188981
AN - SCOPUS:77249143948
SN - 0039-9140
VL - 81
SP - 678
EP - 683
JO - Talanta
JF - Talanta
IS - 1-2
ER -