T1 - A photonic crystal biosensor assay for ferritin utilizing iron-oxide nanoparticles
AU - Peterson, Ross D.
AU - Cunningham, Brian T.
AU - Andrade, Juan E.
N1 - Funding Information:
This project was supported by Vision 20/20 USDA Hatch Project ILLU-971-342 (J.E.A., B.T.C.). Authors thank Sherine George for providing technical suggestions while performing the PC experiments and Thiago Villa for advice and knowledge surrounding biosensors concepts.
PY - 2014/6/15
Y1 - 2014/6/15
N2 - Iron deficiency anemia afflicts 1 in 3 individuals, mostly women and children worldwide. A novel application using iron-oxide nanoparticles (IONPs) and a photonic crystal (PC) optical biosensor as an immunodiagnostic platform for detection of serum ferritin, a biomarker for iron deficiency, is presented. Human liver ferritin (450. kDa), clinical serum controls, and three commercially available ferritin ELISA tests were used to evaluate the PC biosensor assay in terms of inter- and intra-assay variability, spike-recovery (%), limit of detection (LOD), and matrix effects on binding. For the PC biosensor, signal response from label-free, sandwich with secondary antibody (pAb), and pAb functionalized with iron-oxide nanoparticles (FpAb) assays were detected using the Biomolecular Interaction Detection (BIND) system. Bland-Altman analysis was used to evaluate agreement between expected values for ferritin in control sera and each of the detection platforms. Inter- and intra-assay variability of the PC biosensor were both <10%. Percent mean recovery (±%RSD) of ferritin from two control sera samples were 94.3% (13.1%) and 96.9% (7.6%). Use of FpAb in PC biosensor resulted in two orders of magnitude increase in sensitivity compared to label-free assay; capable of measuring serum ferritin as low as 26. ng/mL. In comparison to ELISA tests, the PC biosensor assay had the lowest bias (-1.26; 95% CI [-3.0-5.5]) and narrower limit of agreement (-11.6-9.1. ng/mL) when determining ferritin concentrations from control sera. These proof-of-concept studies support the use of IONPs to enhance detection sensitivity of PC biosensors for determination of biomarkers of nutritional status.
AB - Iron deficiency anemia afflicts 1 in 3 individuals, mostly women and children worldwide. A novel application using iron-oxide nanoparticles (IONPs) and a photonic crystal (PC) optical biosensor as an immunodiagnostic platform for detection of serum ferritin, a biomarker for iron deficiency, is presented. Human liver ferritin (450. kDa), clinical serum controls, and three commercially available ferritin ELISA tests were used to evaluate the PC biosensor assay in terms of inter- and intra-assay variability, spike-recovery (%), limit of detection (LOD), and matrix effects on binding. For the PC biosensor, signal response from label-free, sandwich with secondary antibody (pAb), and pAb functionalized with iron-oxide nanoparticles (FpAb) assays were detected using the Biomolecular Interaction Detection (BIND) system. Bland-Altman analysis was used to evaluate agreement between expected values for ferritin in control sera and each of the detection platforms. Inter- and intra-assay variability of the PC biosensor were both <10%. Percent mean recovery (±%RSD) of ferritin from two control sera samples were 94.3% (13.1%) and 96.9% (7.6%). Use of FpAb in PC biosensor resulted in two orders of magnitude increase in sensitivity compared to label-free assay; capable of measuring serum ferritin as low as 26. ng/mL. In comparison to ELISA tests, the PC biosensor assay had the lowest bias (-1.26; 95% CI [-3.0-5.5]) and narrower limit of agreement (-11.6-9.1. ng/mL) when determining ferritin concentrations from control sera. These proof-of-concept studies support the use of IONPs to enhance detection sensitivity of PC biosensors for determination of biomarkers of nutritional status.
KW - Biosensor
KW - Ferritin
KW - Iron deficiency
KW - Iron-oxide nanoparticles
KW - Photonic crystal
UR - http://www.scopus.com/inward/record.url?scp=84893720229&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84893720229&partnerID=8YFLogxK
U2 - 10.1016/j.bios.2014.01.022
DO - 10.1016/j.bios.2014.01.022
M3 - Article
C2 - 24530833
AN - SCOPUS:84893720229
SN - 0956-5663
VL - 56
SP - 320
EP - 327
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
ER -