TY - GEN
T1 - A Kelvin transmission line pulsing system with optimized oscilloscope ranging
AU - Gerdemann, Alex
AU - Bhatia, Karan
AU - Rosenbaum, Elyse
PY - 2007
Y1 - 2007
N2 - In this work, a custom transmission line pulsing system is built using common laboratory equipment and off-the-shelf components. The combination of Kelvin probing, ground return line length reduction, and an optimized oscilloscope ranging algorithm provide excellent TLP I-V curves and enables highly accurate measurement of device on-resistance.
AB - In this work, a custom transmission line pulsing system is built using common laboratory equipment and off-the-shelf components. The combination of Kelvin probing, ground return line length reduction, and an optimized oscilloscope ranging algorithm provide excellent TLP I-V curves and enables highly accurate measurement of device on-resistance.
UR - http://www.scopus.com/inward/record.url?scp=51849159139&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=51849159139&partnerID=8YFLogxK
U2 - 10.1109/EOSESD.2007.4401735
DO - 10.1109/EOSESD.2007.4401735
M3 - Conference contribution
AN - SCOPUS:51849159139
SN - 158537136X
SN - 9781585371365
T3 - Electrical Overstress/Electrostatic Discharge Symposium Proceedings
SP - 2A.11-2A.19
BT - 2007 29th Electrical Overstress/Electrostatic Discharge Symposium, EOS/ESD
T2 - 2007 29th Electrical Overstress/Electrostatic Discharge Symposium, EOS/ESD
Y2 - 16 September 2007 through 21 September 2007
ER -